Short answer: for most projects, a copper-bonded earth rod (steel with a copper coating) is the balanced choice. Its steel core makes driving easy, while the copper coating gives corrosion resistance and compatibility with copper conductors. Solid copper suits highly corrosive and saline soils, stainless steel suits sites next to buried pipes, tanks and steel structures and installations with cathodic protection, and galvanised steel suits only systems where every part is galvanised. More important than the material itself is that all parts of the earthing system in the soil are made of the same material.
At KALOT Group we offer all four materials. In this guide we explain what each one brings, the minimum sizes the standards require and the part the soil on your site plays in the choice.
Types of earth rod by material
- Solid copper earth rod: copper across the whole section, so a scratch, thread or clamp never exposes any steel. BS 7430 suggests solid copper earth rods for soft or highly corrosive soil with a high salt content. It costs more and, for driving into hard soil, it is softer than a steel earth rod. We offer it in 16 and 20 mm diameters.
- Copper-bonded earth rod (steel with a copper coating): a strong steel core with a copper coating welded to the steel. The standards require a coating of at least 0.25 mm (250 microns) so that it is not stripped during driving. In a 2023 test at the Razi Metallurgical Research Centre, the coating on our copper-bonded earth rod measured 292 to 315 microns. Earth rod sections are joined with a brass coupling so that the electrode reaches the required depth.
- Hot-dip galvanised earth rod: a steel core with a zinc coating. It is the cheapest option, but the zinc coating gets used up in corrosive soil. IEEE 142 and BS 7430 recommend galvanised less for a main electrode, and IEC 60364-5-54 also says galvanised steel must not run from a foundation into the soil. Its logical place is in systems that are galvanised throughout: towers, fences and galvanised steel structures, as well as temporary site earthing.
- 304L and 316 stainless steel earth rod: hard and resistant to corrosion, with a smaller potential difference to steel than copper has. That is why it is a common choice next to buried pipes, tanks and steel structures and in installations with cathodic protection. Grade 316 is for highly corrosive environments.
You will find all our earth rods under Copper-bonded earth rods and Copper, stainless steel and galvanised earth rods.
Minimum standard sizes for earth electrodes
Table 54.1 of IEC 60364-5-54 sets the minimum size of electrodes buried in the soil:
Electrode material and shape | Minimum per Table 54.1 | What we offer |
|---|---|---|
Solid copper earth rod | 15 mm diameter | 16 and 20 mm diameter |
Steel earth rod with copper coating (copper-bonded) | 14 mm diameter, 250 micron coating | 14.2 and 17.2 mm diameter, coating of at least 0.25 mm |
Hot-dip galvanised steel earth rod | 16 mm diameter | 16 and 20 mm diameter, 50 to 70 micron coating |
Stainless steel earth rod | 16 mm diameter | 16 and 20 mm diameter, 304L and 316 |
Copper plate | 2 mm thickness | 660×660 and 660×500, 3 and 5 mm thickness |
On a copper-bonded earth rod, the thickness and adhesion of the coating are the clearest signs of quality: a thin or electroplated coating is stripped during driving and leaves the steel exposed to the soil.
Copper plate or earth rod?
According to BS 7430, an earth rod or tape with the same surface area has a much lower resistance than a plate, which is why the main electrode on most projects is an earth rod. A copper earth pit plate is a dependable answer where driving an earth rod is not possible, such as a hard layer near the surface, a tight space or an area crowded with underground services. In deep pits, galvanised or stainless steel earth pipes are used. To see what resistance each electrode shape gives, read our article on the earth electrode resistance formula.
What part does the soil play in choosing an electrode material?
To choose an electrode material, BS 7430 looks at several soil properties. The most important are:
- Soil resistivity: low-resistivity soil is usually more corrosive and also speeds up galvanic corrosion. Soil resistivity has to be measured on site (how to measure soil resistivity and what soil resistivity is).
- pH and organic acids: acidic and organic soils corrode copper and steel. BS 7430 also warns about the effect of soluble salts, organic acids and acidic soil on copper-coated steel.
- Chlorides and sulphates: in saline soils the zinc coating is used up sooner, and solid copper or stainless steel are the more resistant options.
- Moisture and aeration: wet, low-oxygen soil, especially with sulphate-reducing bacteria, raises the risk of corrosion.
In corrosive or high-resistivity soils, a standard ground improvement material such as GIM is also placed around the electrode. A suitable material must not corrode the electrode itself (specifications of standard ground improvement materials). By contrast, BS 7430 does not consider coke, fly ash, gravel or sand suitable for backfilling around an electrode, and it does not accept aluminium for an electrode in soil.
Galvanic corrosion: when two dissimilar metals are joined in soil
Two dissimilar metals joined in soil form an electrical cell, and the more active metal corrodes. According to IEEE 142, copper is cathodic to steel, with a potential difference of about 0.38 V. So if a copper electrode is connected to a buried steel pipe, tank or structure, the steel corrodes sooner, and the lower the soil resistivity, the worse the corrosion. The common solution in these places is a stainless steel electrode. In installations with cathodic protection, agree the earth electrode material with the cathodic protection designer.
All earthing system parts in the soil should be the same material
One simple rule solves most problems: in soil, copper goes with copper and galvanised with galvanised. That means copper tape or bare copper conductor with a copper-bonded or copper earth rod, and galvanised tape with a galvanised earth rod. BS 7430 also says bare galvanised steel must not be connected to copper or to steel inside concrete. Copper is connected to galvanised structures, such as a tower or cable tray, only in air, above ground, with suitable clamps and anti-corrosion protection. Make connections in the soil with brass earthing clamps or exothermic welding, and keep the top of the electrode accessible in an inspection pit. If the building has foundation earthing, see our article on foundation earthing too.
Summary: which material for which job?
Project conditions | Logical choice |
|---|---|
Most buildings and industrial projects in ordinary soil | Copper-bonded earth rod with copper conductors |
Soft, highly corrosive or very saline soil | Solid copper earth rod, alongside a standard ground improvement material |
Next to a buried steel pipe, tank or structure; installations with cathodic protection | Stainless steel earth rod (316 in highly corrosive environments) |
Fully galvanised system (tower, fence, galvanised structure) or temporary earthing | Galvanised earth rod and tape |
Where driving an earth rod is not possible | Copper plate |
For an accurate choice, send our specialists your soil resistivity measurements, the target resistance, the buried metal structures nearby and the material of your existing conductors. We also carry out soil resistivity measurement and earthing system design. Get in touch through our contact page.