KALOT Group

Certificates and Approvals

Conformity certificates and test reports from accredited laboratories in Iran and abroad for KALOT Group products.

43 documents

Test report

Laboratory test report for the KALweld® conductor-to-conductor T exothermic weld | Power and Water University of Technology

Report no. 95/4220 from the Power and Water University of Technology (Shahid Abbaspour), Ministry of Energy, dated 1395/12/24, prepared at the request of KALOT Group to IEEE 837 and UL 467: freeze cycle (10 cycles), thermal cycle (25 cycles, largest change in weld resistance 3.0%) and 20 kA short-circuit tests on a conductor-to-conductor T weld (CC2) made with KALweld® weld powder and 120 mm² copper conductor. Result of all tests: approved.

Test report

IEC 62561-2 conformity test report for 25×2 mm stainless steel down conductor tape | Niroo Research Institute 2017

Issuer: Niroo Research Institute. Standards: IEC 62561-2 / EN 62561-2.

Test report

Chemical composition test report for 316L stainless steel down conductor tape | Razi Metallurgical Research Centre 2024

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 316L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2026

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2025

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2024

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2023

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2021

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2019

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Chemical composition test report for 304L stainless steel down conductor tape | Razi Metallurgical Research Centre 2018

Issuer: Razi Metallurgical Research Centre. Standards: ASTM A240 (Grade 304L); ASTM E1086.

Test report

Laboratory test report for KALweld® four-way conductor-to-conductor exothermic weld | Power and Water University of Technology

Report no. 95/4221 from the Power and Water University of Technology (Shahid Abbaspour), Ministry of Energy, dated 1395/12/24, prepared at the request of KALOT Group to IEEE 837 and UL 467: freeze cycle tests (10 cycles), thermal cycle tests (25 cycles, largest change in weld resistance 2.8%) and a 20 kA short circuit test on a four-way conductor-to-conductor weld (CC4) using KALweld® weld powder and 120 mm² copper conductor. Result of all tests: approved.

Test report

Load test report for polyethylene earth inspection pit to IEC 62561-5 (2023) | 2026

Test results report from Razi Metallurgical Research Centre, tracking no. 6030-1, issued 1405/06/02, for the load test of a polyethylene earth inspection pit under clause 6.2.2 of IEC 62561-5 (2023). According to the report, three samples were tested with forces of 4, 15 and 30 kN for the Light duty, Medium duty and Heavy duty classes, and the sample is declared Heavy duty class.

Test report

Load test report for concrete earth inspection pit | Razi Metallurgical Research Centre 2020

Issuer: Razi Metallurgical Research Centre. Standards: IEC 62561-5 (2017).

Test report

Compression test report for concrete earth inspection pit | Razi Metallurgical Research Centre 2013

Issuer: Razi Metallurgical Research Centre. Standards: IEC 62561-5 (2011).

Test report

Chemical composition test report for U clamp (U-Bolt) | 2012

Test results report from Razi Metallurgical Research Centre, tracking no. 25572-2, dated 1391/08/10, which determines the chemical composition of a U clamp (U-Bolt) sample by emission spectrometry to DIN EN 15079-07. The sample is a copper-based non-ferrous alloy, and the weight percentages of the elements are given in the report's table.

Test report

ESE performance test report in a high voltage laboratory for the Franklin France Active 4D ESE air terminal | Bazet high voltage laboratory, France 2014

Issuer: Bazet high voltage laboratory, France. Codes and models: Active 4D. Standards: NF C 17-102, test report 1807-14.

Test report

ESE performance test report in a high voltage laboratory for the Franklin France Active 2D ESE air terminal | Bazet high voltage laboratory, France 2013

Issuer: Bazet high voltage laboratory, France. Codes and models: Active 2D. Standards: NF C 17-102, test report 1747-13.

Test report

ESE performance test report in a high voltage laboratory for the Franklin France Active 2D ESE air terminal | Bazet high voltage laboratory, France 2005

Issuer: Bazet high voltage laboratory, France. Codes and models: Active 2D. Standards: NF C 17-102, test report 1261-05 (Saint-Elme Active 2D).

Certificate

Bureau Veritas inspection certificate for the Active 1D+ 60 µs ESE air terminal (AFB20601D) to NF C 17-102 | 2025

Issuer: Bureau Veritas (third-party inspection for Franklin France). Codes and models: AFB20601D; BV certificate 24603101/3/1.1.R. Standards: NF C 17-102 (09/2011) Appendix C.

Certificate

Bureau Veritas inspection certificate for the Active 1D+ 45 µs ESE air terminal (AFB20451D) to NF C 17-102 | 2025

Issuer: Bureau Veritas (third-party inspection for Franklin France). Codes and models: AFB20451D; BV certificate 24603101/3/1.4.R. Standards: NF C 17-102 (09/2011) Appendix C.

Certificate

Bureau Veritas inspection certificate for the Active 1D+ 25 µs ESE air terminal (AFB20251D) to NF C 17-102 | 2025

Issuer: Bureau Veritas (third-party inspection for Franklin France). Codes and models: AFB20251D; BV certificate 24603101/3/1.3.R. Standards: NF C 17-102 (09/2011) Appendix C.

Certificate

GIM LIGHT certificate of conformity with IEC 62561-7, ground improvement materials, 1402

This document contains the results of tests on GIM LIGHT ground improvement material against the requirements of IEC 62561-7, and shows that the product conforms to them.

Test report

pH and solubility test report for GIM ground improvement material | Amirkabir University of Technology 2011

Issuer: Amirkabir University of Technology. Codes and models: GIM. Standards: BS EN 50164-7:2008.

Test report

Leaching test report for GIM ground improvement material | Tarbiat Modares University 2017

Issuer: Tarbiat Modares University. Codes and models: GIM. Standards: EN 12457; IEC 62561-7.