Move your pointer over the image to zoom in
Complete Product Overview
ARG® bonding device for floating roof tanks
Order Code: ARG-18 · ARG-20 · ARG-25
Last updated:
We designed and manufacture the ARG® floating roof tank bonding device at KALOT Group, with in-house capability and creativity, to make the electrical connection between the floating roof and the tank shell. It is used to bond oil and petroleum product storage tanks in refineries, terminals and oil depots.
The roof of these tanks rises and falls as the liquid level changes, so the electrical connection between roof and shell must be maintained throughout this movement. As a retractable bypass conductor, ARG® provides a continuous path for this connection and, together with the shunts, helps reduce potential differences and the risk of lightning-induced sparking at the roof seal.
The ARG® bonding tape extends and retracts with the roof's movement, and its excess length winds onto a reel. This way the conductor does not lie loose and pile up on the roof, and the chance of it snagging on hatches, supports and other equipment is reduced. This mechanism keeps the roof to shell connection in step with the roof's daily movement as the tank fills and empties.
To choose the right device, the tank dimensions, the roof's range of travel and the installation conditions all matter. Our specialists review your project data and drawings and guide you on the model, the number of devices and where to install them. For technical advice and a quote, please contact our specialists.
A roof that moves, a bond that never breaks
A floating roof rises and falls with the liquid level, and its rim seal is non-conductive. At KALOT Group we designed and built ARG® with our own engineering capability and creativity to keep the roof and shell equipotential along this whole travel with the shortest possible conductor.
- Direct bonding of the floating roof to the tank shell, with no power needed
- Reinforced with two stainless steel spiral springs
Two springs, controlled retraction
The device is reinforced with two stainless steel 304 coil springs. These springs keep the braided tape conductor at the shortest possible length at all times, so it does not lie loose on the roof and snag on the seal, drains or roof equipment.
Oil, gas and petrochemical industries
External and internal floating roof tanks for crude oil, petrol, gas oil and other petroleum products all need this equipment to prevent fire and danger.
Installation on a tank in service
ARG® is installed on the top rim of the shell and can be reached from outside for inspection or replacement. Installation and maintenance are carried out under a safe work permit.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Product type | Equipotential bonding device for the floating roof and tank shell (retractable bypass conductor) |
Models | ARG-18, ARG-20 and ARG-25 |
Standard conductor | Flexible tinned copper braided tape, 18, 20 or 25 m long |
Made-to-order conductor | Aluminium braided tape, with connection accessories in the same material |
Braided tape width and thickness | 35 mm and 3 mm |
Body and reel | 316L stainless steel |
Mounting base | Galvanised steel, bolted |
Retraction mechanism | Reinforced with two spiral springs in 304 stainless steel |
Device diameter | About 40 cm |
Design basis | Iranian National Standard INSO 23828:2025 (Lightning protection of aboveground storage tanks for flammable or combustible liquids: code of practice) |
Design and manufacture | KALOT Group |
How many ARG® devices per tank?
Tank circumference (m) | Approximate diameter up to (m) | Minimum ARG® quantity |
|---|---|---|
Up to 60 | 19.1 | 2 |
Up to 90 | 28.6 | 3 |
Up to 120 | 38.2 | 4 |
Up to 150 | 47.7 | 5 |
Up to 180 | 57.3 | 6 |
Up to 240 | 76.4 | 8 |
Up to 300 | 95.5 | 10 |
One ARG® is required for every 30 m of tank circumference or part thereof, with a minimum of two devices spaced evenly around the tank. If the tank has a rolling ladder, one of the bypass conductors runs along it and is bonded to the ladder, roof and shell. Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before purchase.
How the ARG® bonding device for floating roof tanks works
Download How the ARG® bonding device for floating roof tanks works (PDF)
ARG® bonding at different floating roof levels
Download ARG® bonding at different floating roof levels (PDF)
Floating roof rim seal: shunt alone versus shunt with ARG®
Download Floating roof rim seal: shunt alone versus shunt with ARG® (PDF)
Number of ARG® devices by floating roof tank diameter
Download Number of ARG® devices by floating roof tank diameter (PDF)
ARG® alongside other floating roof bonding methods
Feature | ARG® (retractable bonding device) | Fixed bonding cable on the roof | Shunt only |
|---|---|---|---|
Length in the current path | Only the length the roof level requires | Always the full cable length | Short, but reliant on sliding contact |
Inductance with the roof high | Low, and lower as the roof rises | High, and higher when the cable coils | Low |
Connection type | Bolted at both ends, on clean metal | Bolted at both ends | Pressure contact with the inner shell wall |
Dependence on the condition of the shell wall | No | No | High: rust, scale, paint and an out-of-round shell |
Role in the lightning current | Intermediate and long-duration current | Intermediate and long-duration current, with higher inductance | Initial and intermediate parts of the current |
Snagging and wear on the roof | No | High: on seals, supports and hatches | No |
Installation and inspection | From outside the tank, on the shell rim | On the roof | Submerged shunt |
Selection and price enquiry
To select ARG® and request a price, send our specialists the number and diameter of your tanks, the shell height, the total roof travel, the product type, the seal type and the proposed installation location. If you also send a tank drawing or a photo of the shell rim and roof, our specialists at KALOT Group will recommend the right quantity, installation location and connection accessories for you.
Three-dimensional simulator of ARG® on a floating roof tank
ARG® operation video
Documents & Downloads
Drawings & schematics
- How the ARG® bonding device for floating roof tanks worksLanguage: Persian (opens in a new tab)
- ARG® bonding at different floating roof levelsLanguage: Persian (opens in a new tab)
- Floating roof rim seal: shunt alone versus shunt with ARG®Language: Persian (opens in a new tab)
- Number of ARG® devices by floating roof tank diameterLanguage: Persian (opens in a new tab)
Similar & Complementary Products
Frequently Asked Questions
What is a floating roof bypass conductor?
It is a conductor that connects the floating roof directly to the tank shell, so lightning current reaches the shell without arcing or sparking at the roof rim. API RP 545 treats it as the path for the intermediate and long-duration parts of the lightning current. ARG® is the retractable type, and its length shortens and extends as the roof moves.
How does ARG® differ from a shunt? Does it replace the shunt?
No. A shunt is a short strap that presses against the inner wall of the shell and carries the fast part of the current. ARG® is fixed to both the roof and the shell and provides a dedicated path for the intermediate and long-duration parts of the current. Complete tank protection needs both together.
How many ARG® devices does a tank need?
One device for every 30 m of tank circumference or part thereof, with a minimum of two, spaced evenly around the tank. For example, a tank 30 m in diameter has a circumference of about 94 m and needs four ARG® devices.
What should the resistance of a bypass conductor be, and what is it for ARG®?
API RP 545 requires the end-to-end resistance of each bypass conductor, including its connections, to be no more than 0.03 ohm (30 milliohms). The end-to-end resistance of ARG® in all three models, ARG-18, ARG-20 and ARG-25, is below 8 milliohms when fully extended.
How often should ARG® be inspected?
At least once a year, and sooner in corrosive environments. Measure continuity again after any repair or change to a connection, and after a severe lightning strike, inspect the device according to your site procedure.
Do internal floating roof tanks need ARG® as well?
Yes. In these tanks too, an ARG® device should be used to bond the roof to the inner shell. However, because of the fixed roof, these tanks may not need a physical protection system against direct lightning strikes.
Does ARG® need electricity or a control system?
No. ARG® is entirely mechanical: two spiral springs retract the conductor as the roof rises, and the braid pays out as the roof falls. No power supply or electrical wiring is needed in the flammable area.
Does ARG® replace the tank's earthing system?
No. ARG® keeps the floating roof equipotential with the shell, while the earthing system disperses the current into the general mass of the earth. Both must be properly designed and maintained.
What is the warranty on ARG®?
ARG® comes with an 18-month warranty, and the specialists at KALOT Group stay with you through selection, installation, commissioning and periodic inspection.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.