KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original
ARG bonding device for floating roof tanks

Complete Product Overview

ARG® bonding device for floating roof tanks

Order Code: ARG-18 · ARG-20 · ARG-25

Last updated:

We designed and manufacture the ARG® floating roof tank bonding device at KALOT Group, with in-house capability and creativity, to make the electrical connection between the floating roof and the tank shell. It is used to bond oil and petroleum product storage tanks in refineries, terminals and oil depots.

The roof of these tanks rises and falls as the liquid level changes, so the electrical connection between roof and shell must be maintained throughout this movement. As a retractable bypass conductor, ARG® provides a continuous path for this connection and, together with the shunts, helps reduce potential differences and the risk of lightning-induced sparking at the roof seal.

The ARG® bonding tape extends and retracts with the roof's movement, and its excess length winds onto a reel. This way the conductor does not lie loose and pile up on the roof, and the chance of it snagging on hatches, supports and other equipment is reduced. This mechanism keeps the roof to shell connection in step with the roof's daily movement as the tank fills and empties.

To choose the right device, the tank dimensions, the roof's range of travel and the installation conditions all matter. Our specialists review your project data and drawings and guide you on the model, the number of devices and where to install them. For technical advice and a quote, please contact our specialists.


A roof that moves, a bond that never breaks

A floating roof rises and falls with the liquid level, and its rim seal is non-conductive. At KALOT Group we designed and built ARG® with our own engineering capability and creativity to keep the roof and shell equipotential along this whole travel with the shortest possible conductor.

  • Direct bonding of the floating roof to the tank shell, with no power needed
  • Reinforced with two stainless steel spiral springs
  • Two springs, controlled retraction

    The device is reinforced with two stainless steel 304 coil springs. These springs keep the braided tape conductor at the shortest possible length at all times, so it does not lie loose on the roof and snag on the seal, drains or roof equipment.

  • Oil, gas and petrochemical industries

    External and internal floating roof tanks for crude oil, petrol, gas oil and other petroleum products all need this equipment to prevent fire and danger.

  • Installation on a tank in service

    ARG® is installed on the top rim of the shell and can be reached from outside for inspection or replacement. Installation and maintenance are carried out under a safe work permit.

Technical Product Information

Click to view enlarged

Feature

Value

Product type

Equipotential bonding device for the floating roof and tank shell (retractable bypass conductor)

Models

ARG-18, ARG-20 and ARG-25

Standard conductor

Flexible tinned copper braided tape, 18, 20 or 25 m long

Made-to-order conductor

Aluminium braided tape, with connection accessories in the same material

Braided tape width and thickness

35 mm and 3 mm

Body and reel

316L stainless steel

Mounting base

Galvanised steel, bolted

Retraction mechanism

Reinforced with two spiral springs in 304 stainless steel

Device diameter

About 40 cm

Design basis

Iranian National Standard INSO 23828:2025 (Lightning protection of aboveground storage tanks for flammable or combustible liquids: code of practice)

Design and manufacture

KALOT Group

How many ARG® devices per tank?

Tank circumference (m)

Approximate diameter up to (m)

Minimum ARG® quantity

Up to 60

19.1

2

Up to 90

28.6

3

Up to 120

38.2

4

Up to 150

47.7

5

Up to 180

57.3

6

Up to 240

76.4

8

Up to 300

95.5

10

One ARG® is required for every 30 m of tank circumference or part thereof, with a minimum of two devices spaced evenly around the tank. If the tank has a rolling ladder, one of the bypass conductors runs along it and is bonded to the ladder, roof and shell. Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before purchase.

KALOT Group ARG® bonding device for floating roof tanks.

How the ARG® bonding device for floating roof tanks works

How ARG® works: lightning current flows from the floating roof, through the ARG® woven tape and the shunts, to the shell and the earthing network.

Download How the ARG® bonding device for floating roof tanks works (PDF)

ARG® bonding at different floating roof levels

The shortest bond at every roof level: the ARG® tape retracts and unwinds with the roof movement and always stays straight and taut.

Download ARG® bonding at different floating roof levels (PDF)

Floating roof rim seal: shunt alone versus shunt with ARG®

The rim seal problem: without a reliable bypass conductor, the contact between the shunt and the shell sparks in the vapour space; ARG® alongside the shunts creates a better path.

Download Floating roof rim seal: shunt alone versus shunt with ARG® (PDF)

Number of ARG® devices by floating roof tank diameter

How many ARG® devices does your tank need? One device for every 30 m of tank circumference or part of it, and at least two devices.

Download Number of ARG® devices by floating roof tank diameter (PDF)

ARG® alongside other floating roof bonding methods

Feature

ARG® (retractable bonding device)

Fixed bonding cable on the roof

Shunt only

Length in the current path

Only the length the roof level requires

Always the full cable length

Short, but reliant on sliding contact

Inductance with the roof high

Low, and lower as the roof rises

High, and higher when the cable coils

Low

Connection type

Bolted at both ends, on clean metal

Bolted at both ends

Pressure contact with the inner shell wall

Dependence on the condition of the shell wall

No

No

High: rust, scale, paint and an out-of-round shell

Role in the lightning current

Intermediate and long-duration current

Intermediate and long-duration current, with higher inductance

Initial and intermediate parts of the current

Snagging and wear on the roof

No

High: on seals, supports and hatches

No

Installation and inspection

From outside the tank, on the shell rim

On the roof

Submerged shunt

Selection and price enquiry

To select ARG® and request a price, send our specialists the number and diameter of your tanks, the shell height, the total roof travel, the product type, the seal type and the proposed installation location. If you also send a tank drawing or a photo of the shell rim and roof, our specialists at KALOT Group will recommend the right quantity, installation location and connection accessories for you.

Three-dimensional simulator of ARG® on a floating roof tank

Rotate the tank, change the roof level and watch a lightning strike. Choose the model and tank diameter to see how many devices you need.Open full screen

ARG® operation video

ARG®: a moving roof, a continuous connection.Download the video

Frequently Asked Questions

What is a floating roof bypass conductor?

It is a conductor that connects the floating roof directly to the tank shell, so lightning current reaches the shell without arcing or sparking at the roof rim. API RP 545 treats it as the path for the intermediate and long-duration parts of the lightning current. ARG® is the retractable type, and its length shortens and extends as the roof moves.

How does ARG® differ from a shunt? Does it replace the shunt?

No. A shunt is a short strap that presses against the inner wall of the shell and carries the fast part of the current. ARG® is fixed to both the roof and the shell and provides a dedicated path for the intermediate and long-duration parts of the current. Complete tank protection needs both together.

How many ARG® devices does a tank need?

One device for every 30 m of tank circumference or part thereof, with a minimum of two, spaced evenly around the tank. For example, a tank 30 m in diameter has a circumference of about 94 m and needs four ARG® devices.

What should the resistance of a bypass conductor be, and what is it for ARG®?

API RP 545 requires the end-to-end resistance of each bypass conductor, including its connections, to be no more than 0.03 ohm (30 milliohms). The end-to-end resistance of ARG® in all three models, ARG-18, ARG-20 and ARG-25, is below 8 milliohms when fully extended.

How often should ARG® be inspected?

At least once a year, and sooner in corrosive environments. Measure continuity again after any repair or change to a connection, and after a severe lightning strike, inspect the device according to your site procedure.

Do internal floating roof tanks need ARG® as well?

Yes. In these tanks too, an ARG® device should be used to bond the roof to the inner shell. However, because of the fixed roof, these tanks may not need a physical protection system against direct lightning strikes.

Does ARG® need electricity or a control system?

No. ARG® is entirely mechanical: two spiral springs retract the conductor as the roof rises, and the braid pays out as the roof falls. No power supply or electrical wiring is needed in the flammable area.

Does ARG® replace the tank's earthing system?

No. ARG® keeps the floating roof equipotential with the shell, while the earthing system disperses the current into the general mass of the earth. Both must be properly designed and maintained.

What is the warranty on ARG®?

ARG® comes with an 18-month warranty, and the specialists at KALOT Group stay with you through selection, installation, commissioning and periodic inspection.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.