Complete Product Overview
Galvanised steel tape (galvanised earth tape) for foundation earthing and lightning protection
Order Code: GST 303
Last updated:
KALOT Group galvanised earth tape is a solid 30 × 3 mm steel tape with a 90 mm² cross-section and a 70 micron hot-dip galvanised coating, used in earthing and lightning protection as an earth conductor, bonding conductor and down conductor. Its flat width gives a large contact surface with concrete and soil, and it clamps firmly between the flat plates of a clamp without being drilled. Its main uses are foundation earthing inside foundation concrete and as the buried conductor of earth networks whose components are all galvanised steel.
We supply galvanised tape in rolls under order code GST 303, along with galvanised round wire, and we manufacture galvanised earth rods and matching galvanised clamps, so the whole system is one material. Do not connect galvanised steel in soil to copper, brass or stainless steel. If a conductor has to pass from the foundation concrete into the soil, or an electrode is needed beside a reinforced concrete foundation, we recommend a grade 316 stainless steel earth rod or a 35 × 3 grade 316L stainless steel tape.
A flat conductor for foundation earthing and galvanised earth networks
Galvanised tape is used most in two places: inside foundation concrete, as a closed loop connected to the reinforcing bars, and in earth networks whose earth rods, conductors and clamps are all galvanised steel. To choose correctly, weigh up where it will be installed (concrete, soil or air) and the metals around it; our specialists are with you in this choice.
- Solid steel tape, 30 × 3 mm; cross-section 90 mm²
- 70 micron hot-dip galvanised coating; rounded edges; supplied in rolls
- Foundation earthing, galvanised earth networks and down conductors
- Same material as KALOT galvanised earth rods, round wire and clamps
Inside foundation concrete
We install galvanised tape as a closed loop in the foundation concrete, with at least 5 cm of concrete cover on all sides and connected to the reinforcing bars; branches rise inside a concrete column or wall to above ground level or into the building, not through the soil.
In an all-galvanised earth network
In soil, the tape connects galvanised earth rods to each other and to galvanised steel structures whose bases are not connected to concrete reinforcing bars, using KALOT galvanised clamps and no copper or brass parts. The riser conductor is galvanised steel too, not a green and yellow conductor.
Same material as galvanised earth rods, round wire and clamps
Our galvanised earth rod, galvanised round wire, galvanised U clamp and galvanised tape-to-earth rod clamp form an integrated system with this tape; Topic 13 of the Iranian National Building Regulations considers bonding galvanised steel to galvanised steel suitable.
90 mm², 3 mm thick
The nominal cross-section and thickness of GST 303 tape are selected on the basis of the requirements of IEC 62561-2:2018, IEC 60364-5-54 and Topic 13 for hot-dip galvanised steel tape in soil; the same tape also exceeds the minimum size required for tape inside concrete and for down conductors.
Drawings and datasheet
Galvanised tape datasheet (PDF)The section and roll drawing, foundation earthing installation details, foundation earthing schematic, galvanised earth network schematic with earth rods, connection modes and installation steps are all available as PDF files alongside the datasheet.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Product type | Solid steel tape with a galvanised coating; earth conductor, bonding conductor and down conductor |
Material | Steel with a hot-dip galvanised (zinc) coating |
Coating thickness | 70 microns |
Dimensions | 30 × 3 mm, with rounded edges |
Cross-section | 90 mm² |
Weight per metre | 0.73 kg |
Supply form | Roll |
Order code | GST 303 |
Clamps | Galvanised U clamp (tape up to 30 wide on an earth rod or reinforcing bar with a diameter over the ribs of 14 to 34 mm), galvanised clamp for connecting tape to earth rod and round wire (25 to 30 tape on a round conductor of 8 to 16) and galvanised multi-purpose clamp for tape-to-tape connections; inside concrete, the stainless steel multi-purpose clamp is also used |
Compatibility | With galvanised earth rods, round wire and clamps; inside concrete, with reinforcing bars and stainless steel clamps; no copper or brass |
Main application | Foundation earthing; all-galvanised earth networks in soil; bonding of reinforcing bars and structures; down conductors on towers and galvanised steel structures |
Design basis | Nominal cross-section and thickness based on the requirements of IEC 62561-2:2018, IEC 60364-5-54 and Topic 13 of the Iranian National Building Regulations |
Galvanised earth tape code, dimensions and weight
Order code | Width W (mm) | Thickness t (mm) | Cross-section (mm²) | Weight per metre (kg) |
|---|---|---|---|---|
GST 303 | 30 | 3 | 90 | 0.73 |
Galvanised tape is supplied in rolls; W is the tape width and t its thickness. The weight per metre is calculated from the nominal dimensions, with rounded edges and a 70 micron hot-dip galvanised coating. Our products improve continually and the dimensions of some may be updated; please confirm final dimensions with our specialists before you buy.
Section and roll drawing
Download the section and roll drawing (PDF)
Foundation earthing installation details
Download the foundation earthing installation details (PDF)
Structure and supply form of galvanised tape
GST 303 tape is a solid steel strip with rounded edges, 30 mm wide and 3 mm thick, covered by a 70 micron hot-dip galvanised coating. Zinc is more active than steel in soil and air and protects it sacrificially; if the coating is scratched somewhere, the surrounding zinc goes on protecting the steel. The tape is supplied in rolls and is unrolled, straightened and cut to size on site; repair each cut with zinc-rich paint. A cross-section of 90 mm² and a thickness of 3 mm are the size that IEC 62561-2:2018, IEC 60364-5-54 and Topic 13 require for hot-dip galvanised steel tape in soil, and the 70 micron coating exceeds the 63 micron minimum required by IEC 60364-5-54 and Topic 13; the minimum size needed for tape inside concrete and for down conductors is smaller than this.
Click to view enlarged
Uses of galvanised earth tape in earthing and lightning protection
- Foundation earthing (foundation electrode): a closed loop in the foundation concrete, with at least 5 cm of concrete cover and connected to the reinforcing bars; see earthing systems based on foundation earthing.
- Bonding of reinforcing bars and structures: connecting foundation and column reinforcing bars to the earthing system; see bonding and equipotential bonding.
- Buried conductor of a galvanised earth network: connecting galvanised earth rods to each other at a depth of 70 to 80 cm in the soil.
- Earth ring for towers, fences and galvanised steel structures: where no steel inside concrete, including tower foundation reinforcing bars connected to anchor bolts or the structure's base, is connected to the buried conductor.
- Horizontal electrode in rocky or high-resistivity soil: where an earth rod cannot be driven, the tape is laid in a trench and can be surrounded with GIM ground improvement material.
- Down conductor: on towers and galvanised steel structures, in the same material as the structure; for down conductors on walls and facades, we recommend galvanised round wire. Never install a copper conductor above galvanised parts.
- Riser conductor in a galvanised system: galvanised steel instead of a green and yellow conductor, from the earth pit to the structure or measuring point.
Foundation earthing schematic with galvanised tape
Download the foundation earthing schematic (PDF)
All-galvanised earth network with earth rods
Download the galvanised earth network schematic (PDF)
Galvanised tape connection modes with KALOT galvanised clamps
Download connection modes (PDF)
Galvanised tape installation steps
- Mark out the tape route according to the earthing drawing: a closed loop in the building foundation, or a buried conductor between galvanised earth rods. Choose all network components (earth rod, conductor and clamp) in galvanised steel, and mark the position of each branch and joint before you start.
- Unroll the tape and straighten it without hammering the coating. At corners and changes of direction, bend the tape with a bending tool to a gentle radius rather than cutting and rejoining it; one joint fewer is one weak point fewer.
- In the foundation: secure the tape on spacers so that at least 5 cm of concrete covers it on all sides; placing the tape on edge helps concrete fill beneath it. Fix the tape to the reinforcing bars at intervals of no more than 2 m, and make joints that stay in concrete with two clamps on two separate reinforcing bars. Connect tape branches and crossings inside the concrete with the KALOT galvanised or stainless steel multi-purpose clamp, two-way, three-way or four-way. Avoid wedge connections and fixing the tape with tying wire alone.
- Take branches up inside a concrete column or wall to above ground level or into the building; a galvanised conductor does not pass directly from foundation concrete into soil. Wherever the route has to cross soil, use a 16 mm grade 316 stainless steel earth rod or a 35 × 3 grade 316L stainless steel tape and make the change of material inside the concrete: to the earth rod with the galvanised tape-to-earth rod clamp, and to the tape with the KALOT multi-purpose clamp; fully cover this joint with a moisture-proof compound before the concrete is poured.
- Before pouring the concrete, measure the electrical continuity of the loop and branches, and record the tape route and every joint with a drawing and photos.
- Galvanised earth network in soil: dig the trench to a depth of 70 to 80 cm and below the frost line, lay the tape on its floor, then cover it with soft, moist soil, free of stones, building rubble and charcoal, and compact it. In rocky or high-resistivity soil, surround the tape with GIM ground improvement material.
- Run the tape in one piece between two earth pits and make joints only inside the earth pit: fix the tape to the head of the galvanised earth rod with a galvanised U clamp and pour concrete around the earth pit. Tighten the nuts according to the manufacturer's instructions and do not use any copper or brass clamps or conductors.
- Repair every cut, hole or weld with zinc-rich paint; the zinc coating has been lost at these points.
- After installation, connect the branches to the main earthing terminal and to the down conductor connection points, measure the earth resistance and enter the result, with the date, in the earthing system file.
Download the installation steps (PDF)
Installation tools
Open-ended or ring spanner for the clamp nuts, tape bending tool, hacksaw or tape shears, concrete spacers, zinc-rich paint, continuity tester (milliohmmeter), earth resistance tester and a camera to record the route before pouring concrete or backfilling the trench.
Continuity checks, measurement and inspection
Joints in concrete and trenches cannot be seen after the concrete is poured or the trench is filled, so check the tape route and every joint beforehand and record them with a drawing and photos, with an axis number or label visible next to the joint in the photo. After installation, measure the continuity of each branch and the earth resistance, and keep the results, with the date, in the earthing system file. IEC 62305-3:2010 suggests maximum inspection intervals for a lightning protection system: at protection levels I and II, a visual inspection every year and a complete inspection every 2 years; at protection levels III and IV, a visual inspection every 2 years and a complete inspection every 4 years. For sensitive structures, such as office and commercial buildings and crowded places, it suggests a complete inspection every year, and for structures with an explosive materials risk, a visual inspection every 6 months and an electrical test every year. The same standard recommends a visual inspection at least once a year; shorten the intervals in corrosive environments. At each inspection, examine the accessible parts, especially where the tape leaves the concrete and the joints inside the earth pit, for nut tightness, the condition of the zinc coating and signs of corrosion (white zinc rust or red steel rust), and repair any damage. For the measuring method, see how earth terminal resistance is measured.
Choosing and pricing galvanised tape
For a galvanised tape quote, send our specialists the order code GST 303, the length you need in metres and the accessories required (galvanised earth rod, galvanised U clamp, galvanised tape-to-earth rod clamp, galvanised round wire, GIM ground improvement material and earth pit). If you also send the installation location (inside foundation concrete, in soil or on a structure), the soil type and the earthing drawing, our specialists at KALOT Group will be with you in choosing the size and matching clamps. If the project is in a coastal area or has saline groundwater, consult our specialists before choosing galvanised parts.
Click to view enlarged
The resistance of a buried conductor depends above all on its length and the soil resistivity; width and depth have less effect. Even so, the section perimeter of 30 × 3 tape is 66 mm, more than twice that of 10 mm round wire (31 mm), and for the same length its earth resistance is slightly lower. The tape sits between the flat plates of a clamp and is fixed without drilling. Zinc is more active than steel in soil and air and protects the steel beneath it sacrificially; it is consumed slowly in neutral, well-drained soil and quickly in acidic, organic, moist clay, saline and high-chloride soil. Inside concrete, galvanised steel surrounded by more than 5 cm of concrete is well protected against corrosion, according to IEC 60364-5-54. In soil, galvanised steel is more active than copper and steel inside concrete; that is why we choose all the components of a galvanised earth network in galvanised steel and make the passage from concrete to soil with 316 stainless steel. Among our earth tapes, galvanised tape has the lowest metal value.
Advantages of KALOT galvanised tape
- Economical: the lowest metal value among KALOT earth tapes; well suited to large networks and long runs.
- Same material as the galvanised system: forms an integrated system with KALOT galvanised earth rods, galvanised round wire and galvanised clamps.
- Larger contact surface: a 66 mm section perimeter, more than twice that of 10 mm round wire; more contact with concrete and soil.
- Connection without drilling: with our galvanised clamps, the tape is gripped between the plates and keeps its full cross-section.
- One conductor for foundation, soil and structure: foundation electrode, reinforcing bar bonding, buried conductor of a galvanised network and down conductor on galvanised structures.
- 70 micron coating and rounded edges: a 70 micron hot-dip galvanised coating, above the 63 micron minimum that IEC 60364-5-54 and Topic 13 require for galvanised tape in soil, with rounded edges.
- Cross-section based on requirements: nominal 90 mm² with a thickness of 3 mm, based on the requirements of IEC 62561-2:2018, IEC 60364-5-54 and Topic 13 for hot-dip galvanised steel tape in soil.
Choosing the tape by its role in the design
Conductor role | Installation location | Minimum hot-dip galvanised steel tape size in the standards | Our recommendation |
|---|---|---|---|
Down conductor | On towers and galvanised steel structures | 50 mm² tape (recommended thickness 2.5) | GST 303 |
Bonding conductor and earthing conductor | In concrete and in air | Steel, 50 mm² | GST 303 |
Foundation electrode (the loop inside concrete and its branches) | In concrete | 75 mm² tape, 3 thick | GST 303 |
Buried conductor and earth ring in soil | Soil, 70 to 80 cm deep | 90 mm² tape, 3 thick, with a 63 micron coating | GST 303, in all-galvanised networks with no steel inside concrete connected to them |
Sizes are from IEC 62561-2:2018, IEC 62305-3:2010, IEC 60364-5-54 and Topic 13 of the Iranian National Building Regulations; the design sets the final size of each conductor. For conductor and electrode materials, see earth electrode materials.
See these products too
Product | When |
|---|---|
A vertical electrode in the same material; the tape connects the earth rods to each other in the soil. | |
A 10 mm round conductor for foundation earthing, down conductors and riser conductors. | |
Galvanised clamp for connecting tape to earth rod and round wire | Connects tape to round wire, reinforcing bar and 16 mm earth rods without drilling the tape. |
Connects tape up to 30 mm wide to the head of an earth rod or reinforcing bar. | |
For the passage from foundation concrete to soil and for corrosive soils; in soil, grade 316L in size 35 × 3. | |
An electrode beside reinforced concrete foundations; grade 316 in soil. | |
For trenches in rocky or high-resistivity soil. | |
For an inspectable connection on the top of the earth rod; concrete is poured around it. | |
A lightweight pit for the same connection; concrete is also poured around it. |
IEC 62561-2:2018 (lightning protection system components; conductors and earth electrodes) gives, for solid hot-dip galvanised steel tape, a minimum earth electrode cross-section of 90 mm² with a recommended thickness of 3 mm and a minimum air termination and down conductor cross-section of 50 mm² with a recommended thickness of 2.5 mm, and sets the manufacturing tolerance on cross-section at minus 3 percent. The nominal cross-section and thickness of GST 303 tape are selected on the basis of the requirements of this standard.
IEC 60364-5-54:2011 (earthing arrangements and protective conductors) requires, for hot-dip galvanised steel tape in soil, a cross-section of 90 mm², a thickness of 3 mm and a zinc coating of 500 g/m² (63 microns), and requires the tape to be rolled or slit with rounded edges (our tape has a 70 micron coating and rounded edges); for steel tape inside concrete, 75 mm² with a thickness of 3 mm is enough. An annex to the same standard recommends, for foundation electrodes, concrete cover of more than 5 cm, placing the tape on edge, connecting it to the reinforcing bars at intervals of no more than 2 m and recording it with a drawing and photos before the concrete is poured, and its main text requires that a hot-dip galvanised steel connection leaving a foundation electrode must not be buried in soil.
IEC 62305-3:2010 (protection of structures against lightning) sets the minimum cross-section of solid hot-dip galvanised steel tape at 90 mm² for earth electrodes and 50 mm² for down conductors. The standard accepts galvanised steel in air, in concrete and in low-corrosivity soil, points out that a galvanic connection with copper can destroy it, and states that a copper part must not be installed above a galvanised one. According to the same standard, galvanised tape can be connected directly to the reinforcing bars inside foundation concrete, but an electrode in soil connected to steel inside concrete must be stainless steel or copper; and it does not recommend galvanised steel inside concrete in coastal areas or where the groundwater is saline. The same standard points out that galvanised steel may corrode in clay or moist soil and, because the behaviour of a zinc coating in concrete depends on concrete and groundwater conditions, recommends using galvanised steel in concrete after checking the project conditions.
IEC 62305-3:2010 prefers an earth ring at least 0.5 m below ground; IEC 60364-5-54 also points out that additional earthing arrangements around and near a building with a foundation electrode should be made of steel other than hot-dip galvanised steel. That is why we use galvanised tape in soil only for all-galvanised networks on towers and steel structures.
Topic 13 of the Iranian National Building Regulations (1395 edition) specifies, for hot-dip galvanised steel tape with rounded edges, a cross-section of 90 mm², a thickness of 3 mm and a 63 micron coating, and for steel tape inside concrete, 75 mm² with a thickness of 3 mm, and requires horizontal electrodes at a depth of 0.5 to 0.8 m. In its metal compatibility table, when galvanised steel is the electrode with the smaller area, it considers bonding it to galvanised steel suitable, and bonding it to steel inside concrete, copper, tinned copper and stainless steel of larger area unsuitable. The nominal cross-section and thickness of GST 303 tape are selected on the basis of the requirements of this topic.
The guideline for installing earthing systems in buildings also requires 90 mm², a thickness of 3 mm and a 63 micron coating for hot-dip galvanised steel tape, places horizontal electrodes below the frost line and at a depth of at least 0.7 m, and points out that tape is cut and drilled before galvanising, and that if it is cut or drilled afterwards, the spot is galvanised again or protected with a suitable coating, such as zinc-based paint.
BS 7430:2011 (code of practice for earthing) requires unprotected buried tape to be at least 3 mm thick, does not allow tape to be drilled for a bolt with a diameter of more than one third of its width, and points out that a bare galvanised steel electrode must not be connected to copper or to steel inside concrete. EN 50522 (earthing of installations above 1 kV) requires, for hot-dip galvanised steel tape with rounded edges, 90 mm², a thickness of 3 mm and a zinc coating of 63 microns at any point and 70 microns on average, and prefers horizontal electrodes at a depth of 0.5 to 1 m.
Galvanised steel tape: section and use
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
- Galvanised tape cross-section and roll drawingLanguage: Persian (opens in a new tab)
- Foundation earthing execution details for galvanised tapeLanguage: Persian (opens in a new tab)
- Foundation earthing schematic with galvanised tapeLanguage: Persian (opens in a new tab)
- Galvanised earthing network schematic with galvanised tapeLanguage: Persian (opens in a new tab)
- Galvanised tape connection modesLanguage: Persian (opens in a new tab)
- Galvanised tape installation stepsLanguage: Persian (opens in a new tab)
Frequently Asked Questions
What is galvanised earth tape and where is it used?
Galvanised earth tape is a solid steel strip with a zinc coating that carries fault current and lightning current in earthing and lightning protection systems. Our GST 303 tape is 30 mm wide and 3 mm thick. It is mainly used for foundation earthing inside foundation concrete, reinforcing bar bonding, buried conductors in all-galvanised earth networks and down conductors on galvanised steel structures.
What is the minimum size of galvanised tape for earthing in soil?
IEC 60364-5-54 and Topic 13 of the Iranian National Building Regulations require hot-dip galvanised steel tape in soil to have a cross-section of at least 90 mm² with a thickness of 3 mm, and IEC 62561-2:2018 also gives 90 mm² with a recommended thickness of 3 mm: in other words, 30 × 3. IEC 60364-5-54 and Topic 13 also require this tape to have a zinc coating of at least 63 microns and rounded edges; our GST 303 tape has a 70 micron coating and rounded edges. For tape inside concrete, 75 mm² with a thickness of 3 mm is enough, and for down conductors, 50 mm². The nominal cross-section and thickness of GST 303 tape are selected on the basis of the requirements of these same standards.
What is the difference between hot-dip and cold galvanising?
In hot-dip galvanising, the steel is dipped in molten zinc and gains a thick coating bonded to the steel; cold (electro) galvanising deposits a much thinner layer of zinc. Earthing standards set electrode and buried conductor sizes for hot-dip galvanised steel, and the coating on our galvanised tape is hot-dip galvanised.
How much does one metre of 30×3 galvanised tape weigh?
Each metre of 30 × 3 galvanised tape (GST 303) weighs 0.73 kg, of which 0.70 kg is steel and the rest is the 70 micron zinc coating. This weight is calculated from the nominal dimensions, the rounded edges and the densities of steel and zinc. When ordering, tell us the length you need in metres.
Which is better, galvanised tape or copper tape? Can they be connected to each other?
Each has its place. Copper tape conducts far better and lasts longer in corrosive soils, but its metal value is tens of times higher; galvanised tape is economical and is used in foundation earthing and galvanised earth networks. Never connect the two: in soil, galvanised steel is the more active metal compared with copper, and when joined to copper or brass its zinc coating corrodes faster. Do not even install a copper part above a galvanised one, because copper particles washed off by rain eat away the zinc.
Galvanised tape or galvanised round wire: which should we choose?
Both have the size needed for foundation electrodes and buried conductors: 30 × 3 tape with 90 mm² and our 10 mm galvanised round wire with 78 mm². The resistance of a buried conductor depends above all on its length. Tape has a larger contact surface with soil and concrete and sits neatly between the flat plates of a clamp; round wire needs no particular orientation in concrete, bends more easily along complex reinforcing bar routes and also serves for down conductors and roof networks. The design and the project's clamps decide the choice.
Is galvanised tape suitable for foundation earthing?
Yes. IEC 60364-5-54 and IEC 62305-3:2010 accept galvanised steel tape for foundation electrodes inside concrete and allow it to be connected directly to reinforcing bars; IEC 62305-3:2010 recommends using it after checking the project's concrete and groundwater conditions. Install the tape as a closed loop, with at least 5 cm of concrete cover on all sides and connected to the reinforcing bars. Take branches up inside a concrete column or wall to above ground level or into the building; a galvanised conductor does not pass directly from concrete into soil. Wherever the route has to cross soil, use a 16 mm grade 316 stainless steel earth rod or a 35 × 3 grade 316L stainless steel tape and make the change of material inside the concrete: to the earth rod with the galvanised tape-to-earth rod clamp, and to the tape with the KALOT multi-purpose clamp; cover the joint with a moisture-proof compound. If moisture insulation (for example plastic sheet thicker than 0.5 mm) or thermal insulation is installed under or around the foundation, the foundation concrete is separated from the soil and the loop inside it is not an earth electrode on its own; install the electrode outside the insulation, in 316L stainless steel. IEC 62305-3:2010 does not recommend galvanised steel inside concrete in coastal areas or where the groundwater is saline; for these projects we recommend grade 316L stainless steel tape and a grade 316 stainless steel earth rod, and our specialists are with you in choosing the conductor material. See the details in earthing systems based on foundation earthing.
At what depth is galvanised tape installed in soil?
Topic 13 of the Iranian National Building Regulations requires horizontal electrodes at a depth of 0.5 to 0.8 m, and IEC 62305-3:2010 prefers an earth ring at least 0.5 m below ground; the guideline for installing earthing systems in buildings requires at least 0.7 m. We recommend a depth of 70 to 80 cm, below the frost line. Backfill the trench with soft, moist soil, free of stones, building rubble and charcoal, and compact it. Galvanised tape in soil is for a network in which every component is galvanised and no steel inside concrete is connected to it, such as the earth ring of a tower or steel structure; around a building that has foundation earthing, we recommend a grade 316 stainless steel earth rod.
Which clamp connects galvanised tape to an earth rod, round wire and reinforcing bar?
In soil, run the tape in one piece between two earth pits and make the connection inside the earth pit with a galvanised U clamp (tape up to 30 mm wide) on the head of a 16 or 20 mm galvanised earth rod. Inside concrete, the galvanised clamp for connecting tape to earth rod and round wire fixes 25 to 30 tape to a round conductor of 8 to 16 mm: galvanised round wire, reinforcing bar, or a 316 stainless steel earth rod of 16 mm diameter for the passage into soil. Make joints that stay in concrete with two clamps on two separate reinforcing bars. Tape-to-tape connections, two-way, three-way or four-way, are made with the KALOT multi-purpose clamp: only galvanised inside the earth pit, and galvanised or stainless steel inside concrete. Tighten the nuts according to the manufacturer's instructions and do not use brass or copper clamps.
Can galvanised tape be cut, drilled or welded?
Yes, but the zinc coating is lost where the tape is cut, drilled or welded and must be repaired with zinc-rich paint. Connecting with clamps, which do not drill the tape, is simpler, and at corners bend the tape rather than cut it. If a hole is needed, BS 7430 does not allow a bolt diameter of more than one third of the tape width; for 30 mm tape, that means a 10 mm bolt or smaller. Welding tape to reinforcing bars is done only with the agreement of the structural designer.
Can galvanised tape also be used as a down conductor?
Yes. For down conductors in hot-dip galvanised steel tape, IEC 62305-3:2010 requires a cross-section of at least 50 mm², and 30 × 3 tape exceeds that. On towers and galvanised steel structures, galvanised tape is the same material as the structure; for down conductors on walls and facades, we recommend galvanised round wire. Never install a copper conductor above galvanised parts.
How thick is the galvanised coating on KALOT tape?
Our tape has a hot-dip galvanised coating 70 microns thick, and its edges are rounded. IEC 60364-5-54 and Topic 13 of the Iranian National Building Regulations set a minimum coating thickness of 63 microns for hot-dip galvanised steel tape in soil. Repair any cut or hole with zinc-rich paint so the coating stays continuous.
What does the price of galvanised tape depend on, and how do I get a quote?
The price depends on the length, the number of rolls and the current prices of steel and zinc. Among KALOT earth tapes, galvanised tape has the lowest metal value. For today's price, send our specialists the order code GST 303, the length you need and the accessories.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.