Move your pointer over the image to zoom in
Complete Product Overview
Round wire to steel structure and earth bar clamp (RWSC 010)
Order Code: RWSC 010
Last updated:
The round wire to steel structure clamp connects round wire (a solid round conductor) to steel columns and beams, steel structures or an earth bar with no welding and no cable lug. Its cylindrical body is made of galvanised steel and seats on a hole in the structure or the bar with one M10 bolt; the round wire passes through the 12 mm cross hole in the body and a second bolt holds it firmly in the body.
We make this clamp for jobs where the down conductor, bonding conductor or earthing conductor is round wire and has to reach the steel frame of a building, a steel shed structure, an equipment base or an earth bar. To choose the right clamp for each connection and to ask for a price, contact our experts.
Bolted connection, no welding, no cable lug
A solid round wire cannot be crimped into a cable lug the way a stranded conductor can. This clamp takes the conductor straight into its cross hole and needs only one hole for an M10 bolt in the structure; the galvanised coating or paint of the structure is not damaged by welding either.
One clamp for structures and bars
It fits column and beam flanges, connection lugs and angle brackets, metal equipment frames and the holes of earth bars and bonding bars. Before tightening, you turn the body so that the cross hole lines up with the route of the round wire.
A through conductor that can be undone
The round wire passes through the body without being cut and can carry on to the next point. The connection is bolted, so it can be opened and closed again for checks and measurements during periodic inspections.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Product type | Bolted clamp for connecting round wire to steel structures and earth bars |
Order code | RWSC 010 |
Conductor | Round wire (solid round conductor), 8 and 10 mm in diameter |
Round wire hole | 12 mm, in the middle of the body |
Body thread | M10, right through along the body axis |
Body diameter | 24 mm |
Body length | 34 mm |
Body material | Galvanised steel |
Bolts | Two M10 hex bolts with each clamp; galvanised or stainless steel, as you choose |
Fixing to the structure or bar | One M10 bolt that passes through the hole in the structure or bar from the back and screws into the body thread |
Holding the round wire | The second M10 bolt, from the free end of the body |
Where to use | Connections above ground |
Click to view enlarged
The clamp body is a galvanised steel cylinder 24 mm in diameter and 34 mm long. The 12 mm cross hole sits exactly in the middle of the body, 17 mm from each end, and the M10 thread runs the full length of the body.
Feature | Size |
|---|---|
Order code | RWSC 010 |
Body length | 34 mm |
Body diameter | 24 mm |
Round wire hole | Ø12 mm |
Hole centre from each end | 17 mm |
Axial thread (through) | M10 |
Round wire diameter | 8 · 10 mm |
Click to view enlarged
Each RWSC 010 clamp has three parts:
- Galvanised steel body with a cross hole and an M10 thread
- M10 bolt for fixing the body to the structure or the earth bar
- M10 bolt for securing the round wire
The bolts are supplied galvanised or in stainless steel. The round wire and the structure or bar shown in the drawing are outside the clamp pack.
Click to view enlarged
Installation steps
- Hole and contact surface: Prepare a hole for an M10 bolt in the steel structure or the earth bar and clean around the hole down to bare metal.
- Fixing the body: Pass the M10 bolt through the hole from the back and screw the body onto it. Line the cross hole of the body up with the route of the round wire and tighten the bolt.
- Passing the round wire: Pass the round wire through the cross hole of the body and straighten it along its route.
- Securing the round wire: Screw the second bolt into the free end of the body and tighten it until the round wire is held firmly in the body.
Site notes
- Agree any drilling of the main structural members with the structural engineer or the site supervisor; where the structure has a connection lug or angle bracket, fix the clamp to that.
- Remove paint, rust and grease from where the body seats, so that metal touches metal.
- Pass the round wire through so that its end stands a little proud of the body.
- This clamp is for connections above ground; make connections that are buried in soil with exothermic welding.
- During periodic inspections of the earthing and lightning protection system, check that both bolts are tight.
Click to view enlarged
Where it is used
- Steel frames and structures: Connecting a round wire down conductor or bonding conductor to the columns, beams and bracing of steel-framed buildings, sheds and industrial halls.
- Earth bars and bonding bars: Fixing round wire directly to one of the holes of the bar, with no cable lug.
- Equipment bases and frames: Bonding chassis, equipment bases, railings and small metal structures that have a drilled lug or angle bracket.
Reference standards
- IEC 62561-1 sets out the requirements and tests for the connection components of a lightning protection system, including clamps and bolted connections.
- IEC 62305-3 provides for the use of the natural metal components of a structure, such as a continuous steel frame, as part of the lightning protection system; the system designer checks the electrical continuity and the dimensions of these components.
Round wire to steel structure and earth bar clamp
Documents & Downloads
Drawings & schematics
- Dimensional drawing of the round wire to steel structure clamp (PDF)Language: Persian (opens in a new tab)
- Exploded view of the round wire to steel structure clamp (PDF)Language: Persian (opens in a new tab)
- Installation steps for the round wire to steel structure clamp (PDF)Language: Persian (opens in a new tab)
- Connection modes of the round wire clamp: steel structure and earth bar (PDF)Language: Persian (opens in a new tab)
Frequently Asked Questions
How does this clamp differ from a weld-on earth boss?
The steel earth boss is welded to the structure and the conductor is fixed to its stud with a cable lug. The round wire clamp needs no welding: it seats on a hole in the structure or the bar with one M10 bolt and holds the solid round wire directly in its cross hole.
What is needed on the structure to fit this clamp?
One hole for an M10 bolt and a clean contact surface. On an earth bar you use the holes of the bar itself; on a structure, a connection lug or angle bracket, or a hole drilled in agreement with the structural engineer.
Can round wire be connected to a steel column or beam without welding?
Yes. That is what this clamp is for: the body is bolted to the structure and the round wire is secured in the body by the second bolt; neither welding nor a cable lug is needed.
Which round wire diameters does it take, and what comes with it?
It takes 8 and 10 mm round wire. Each RWSC 010 clamp is supplied with two M10 hex bolts: one to fix the body to the structure or bar and one to secure the round wire. We have the bolts galvanised or in stainless steel; tell us the bolt material when you order.
Can copper round wire be connected to a steel structure with this clamp?
The body of this clamp is galvanised, and copper is joined to galvanised steel only in air and above ground. Cover the joint with an anti-corrosion coating and do not run the copper conductor above galvanised parts, so that rainwater does not run off the copper onto the galvanised steel. For a conductor of the same material as a galvanised structure, we suggest galvanised steel wire (round wire).
Can this clamp be used in soil or concrete?
This clamp is for connections above ground. We make buried connections with exothermic welding, which gives a permanent joint.
Which clamp suits bare stranded copper conductor?
This clamp is designed for round wire. For connecting bare copper conductor to plates and steel structures we have the two-piece TECD clamp and the one-piece TECS clamp.
Can the steel frame of a building act as a down conductor?
IEC 62305-3 provides for the use of the natural metal components of a structure, provided they are electrically continuous and of adequate dimensions. The decision rests with the designer of the lightning protection system; this clamp connects the round wire to that frame.
How do we join two round wires?
For round wire to round wire we have the galvanised cross clamp, and for round wire to reinforcing bar the galvanised wire to rebar clamp. All the clamps of this family are on the earthing and bonding clamps page.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.