Surge Protection Design and SPD Selection

At KALOT Group we design surge protection and select surge protective devices (SPDs) to limit transient overvoltages caused by lightning and switching, reducing the likelihood of damage and disruption to electrical and electronic systems. The design is based on the supply characteristics, the exposure to overvoltages, the withstand of the equipment and the coordination of the SPDs.

Staged SPD design to protect switchboards and sensitive equipment.

We choose the design references to suit the type of circuit, the equipment, the applicable regulations and the requirements of each project.

Our surge protection and SPD design services

Figure 1. Staged surge protective device (SPD) layout: the effective protection level of each SPD must stay below the impulse withstand of the equipment at that location (Uw values to IEC 60364-4-44 for a 230/400 V network).
  • Design basis: We review the supply characteristics and earthing arrangement, the sources of overvoltage, the lightning protection status, incoming services and the impulse withstand of the equipment. We then set the protection needs and design criteria.
  • Protection layout and stages: We define where SPDs are installed: at the service entrance, at main and sub-distribution boards, and close to sensitive equipment. We also choose the connection arrangement and protection modes to suit the lightning protection zones and the distribution structure.
  • SPD type and specification: We select Type 1, 2, 3 or combined SPDs for AC circuits, and set the maximum continuous operating voltage, voltage protection level and impulse current capability. We also check the withstand and safe behaviour of the SPD under temporary overvoltages, according to the supply characteristics and the application.
  • Coordination and installation requirements: We check energy coordination between SPDs using the manufacturer’s technical data. We verify short-circuit withstand and coordination with disconnectors and backup protection against the prospective short-circuit current at the point of installation. We specify the length, routing and cross-section of the connecting conductors and the bonding method, then compare the effective protection level at the equipment with its impulse withstand.
  • Signal lines and special applications: We select SPDs for data, telecom, control and instrumentation lines according to their electrical characteristics and signal transmission needs. Where relevant, we also address the protection requirements of DC circuits and solar PV systems.
  • Documentation and technical review: We prepare layout and connection drawings, equipment schedules and specifications, and inspection and status monitoring requirements. We also review existing designs and SPDs and recommend improvements in light of operating conditions and what can practically be installed.
Figure 2. Voltage drop in the connecting leads adds to the protection level of the surge protective device (SPD), so Up,f = Up + ΔU; IEC 60364-5-53 recommends a total lead length of no more than 0.5 m.
Figure 3. Parameters that determine the right surge protective device (SPD) for each location, and the test waves of Type 1, 2 and 3 SPDs to IEC 61643-11.

Related articles and services

Surge protection works best alongside a sound lightning protection design and earthing and bonding design.

You will find the SPDs for your design in our surge arresters and overvoltage protection range. Press the “Request a Technical Consultation” button and our engineers will contact you to discuss your project.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.