KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original

Periodic Inspection and Maintenance of Earthing and Lightning Protection

At KALOT Group we inspect and maintain earthing and lightning protection systems to identify wear, put defects right and keep the systems performing. We deliver this service in line with the relevant references, including IEC 62305-3 and BS 7430, the project documents and the manufacturers’ instructions.

Periodic inspection and recording of defects in protection systems.

For early streamer emission (ESE) systems based on NF C 17-102, the inspection and maintenance requirements of that standard also apply.

Our earthing and lightning protection inspection and maintenance services

Figure 1. Inspection and maintenance form a repeating cycle, and each round closes by setting the date of the next inspection.
  • Inspection and maintenance plan: We review the system documents and records, then set the scope and frequency of visual and full inspections to suit the protection level, the environment and operating needs. We also plan safety measures, and extra inspections after a confirmed or suspected lightning strike, visible damage or significant changes to the structure or installations.
  • Inspecting components, connections and protective paths: We inspect air terminals, down conductors, accessible parts of the earthing system and bonding connections. We check for corrosion and mechanical damage, check the tightness of connections and supports, and assess how changes to the structure or equipment affect the zone of protection, bonding and separation distances.
  • Periodic tests and assessing results: We carry out continuity tests and measure earth resistance or, where needed, impedance, to suit the type and scope of the inspection. Results are assessed against the applicable standard and the approved design requirements, and compared with earlier records, taking into account the environment and how the system was connected during the test.
  • Checking air terminals and related equipment: We check testable air terminals according to the manufacturer’s instructions. We review lightning counter records, the status indicators and fault alarm systems of SPDs where fitted, and the related connections and backup protection.
  • Maintenance and repairs: We correct faulty connections, check and restore the fixing of components, repair corrosion protection and replace damaged parts in line with the approved specifications and the manufacturer’s instructions. Changes that affect the design are referred for technical review, and the necessary tests are carried out after repair.
  • Records and follow-up: The report covers inspection findings, test methods and results, any limits on the inspection and the work carried out. Critical defects are reported to the operator immediately, corrective work is prioritised, and the outcome of the follow-up check is recorded. Records are updated and the next inspection date is set.
Figure 2. Inspection covers air terminals, down conductors, test joints, earth connections, the counter and the indicators on surge protective devices (SPDs).
Figure 3. Each test result is compared with past records and similar conditions, and defects are prioritised (values and years are illustrative).

Related articles and services

To learn more, read our guide to ESE lightning protection and NF C 17-102. Further tests are described under earthing system testing and earth resistance measurement.

You will find replacement parts in our lightning protection products and ESE air terminals. Press the “Request a Technical Consultation” button and our engineers will contact you to discuss your project.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.