ARG bonding device for floating roof tanksARG® bonding device for floating roof tanks
We designed and manufacture the ARG® floating roof tank bonding device at KALOT Group, with in-house capability and creativity, to make the electrical connection between the floating roof and the tank shell. It is used to bond oil and petroleum product storage tanks in refineries, terminals and oil depots. The roof of these tanks rises and falls as the liquid level changes, so the electrical connection between roof and shell must be maintained throughout this movement. As a retractable bypass conductor, ARG® provides a continuous path for this connection and, together with the shunts, helps reduce potential differences and the risk of lightning-induced sparking at the roof seal. The ARG® bonding tape extends and retracts with the roof's movement, and its excess length winds onto a reel. This way the conductor does not lie loose and pile up on the roof, and the chance of it snagging on hatches, supports and other equipment is reduced. This mechanism keeps the roof to shell connection in step with the roof's daily movement as the tank fills and empties. To choose the right device, the tank dimensions, the roof's range of travel and the installation conditions all matter. Our specialists review your project data and drawings and guide you on the model, the number of devices and where to install them. For technical advice and a quote, please contact our specialists.