Galvanised cross clamp for conductor-to-conductor connections (round wire to round wire)

Last updated:

The KALOT Group galvanised cross clamp, also called a "galvanised four-way clamp" or "cross clamp", joins two galvanised steel round wires or galvanised conductors where they cross, in an X shape. It is made of two identical pressed plates, each with a diagonal round groove. The plates fit together with their grooves at right angles, each conductor sits in the groove of one plate, and two M6 bolts press the conductors together at the crossing point.

Its main use is in foundation earthing: it joins the crossings and branches of the galvanised round wire in a foundation earth electrode with a firm bolted connection before the concrete is poured. For carrying lightning current, this connection replaces tying with reinforcement tie wire. It is also used at the crossings of roof air termination networks built with galvanised round wire. The clamp is the same material as galvanised conductors and is not used next to copper; for copper conductors we recommend our four-way conductor-to-conductor clamp. Code GLSC 5095 clamps round conductors from 50 to 95 mm², and our specialists are at your side for selection and enquiries.

Galvanised cross clamp for foundation earthing round wire crossings

To choose this clamp, check three things: the material of both conductors (galvanised, never copper), their cross-section or diameter, and the joint type (four-way or three-way).

  • Foundation earth electrode crossings and branches
  • Two round galvanised conductors, 50 to 95 mm²
  • Four-way or three-way joint, at 90 degrees
  • Two pressed galvanised steel plates, two M6 bolts
  • Two diagonal grooves, 90-degree crossing

    Each plate has a round groove running across its width at 45 degrees. The two plates close over the crossing with their grooves at right angles, and each conductor sits in its own groove, so the two conductors are pressed together at the centre of the clamp.

  • Connecting foundation earthing crossings

    In a foundation earth electrode, galvanised round wire runs as a closed ring and mesh through the building's footing. This clamp connects its crossings and branches before the concrete is poured.

  • Material: galvanised steel, matching the round wire

    The two plates are pressed from 2 mm galvanised steel sheet, and the bolts and nuts are also galvanised steel. The clamp is the same material as galvanised round wire and conductors, and must not be placed next to copper.

  • Code GLSC 5095 and drawings

    You will find the dimensions of code GLSC 5095 in the technical specifications tab, in the dimensional drawing, technical drawing and exploded view, and in the galvanised cross clamp datasheet.

    Galvanised cross clamp datasheet (PDF)
  • Advice from KALOT Group specialists

    When you enquire, send us the material and size of both conductors (round wire diameter or stranded conductor cross-section), the joint type (four-way or three-way), the installation location and the quantity needed, and our specialists will confirm the right clamp and the price.

Technical Product Information

Click to view enlarged

Feature

Value

Type

Two-plate pressed cross clamp for an X connection of two round conductors

Material

Galvanised steel (plates, bolts and nuts)

Plates

Two identical plates of 2 mm steel sheet, 80 × 25 mm, rounded corners, with a diagonal round groove and KALOT engraving

Groove

45 degrees to the plate length; 9 mm outer radius; projects 7 mm from the plate surface

Holes

Two 8 mm holes in each plate, 56 mm centre to centre

Bolts

Two M6 hexagon bolts, 25 mm long

Nuts

Two M6 hexagon nuts

Weight

83 g (complete set)

Suitable conductor

Galvanised steel round wire or stranded conductor

Conductor cross-section

50 to 95 mm² (round wire 8 to 11 mm)

Joint arrangement

X crossing at 90 degrees; four-way (both conductors run through) or three-way (branch)

Do not use with

Copper conductor

Connection type

Bolted

Main application

Crossings and branches of foundation earth electrodes

Other locations

Crossings of roof air termination networks and galvanised bonding conductors

Code

⁦GLSC 5095⁩

Code and dimensions (GLSC)

Code

Conductor cross-section (mm²)

Round wire diameter (mm)

Plate length (mm)

Plate width (mm)

Weight (g)

⁦GLSC 5095⁩

⁦50-95⁩

⁦8-11⁩

⁦80⁩

⁦25⁩

⁦83⁩

Diameters and dimensions are in millimetres and cross-sections in square millimetres; the weight is for the complete set (two plates, two bolts and two nuts). Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before you buy.

Dimensional drawing

Dimensional drawing of the galvanised cross clamp with dimensions and a table of codes.

Download the dimensional drawing (PDF)

Technical drawing

Technical drawing of the plate of the galvanised cross clamp with all dimensions.

Download the technical drawing (PDF)

Exploded view

Exploded view of the galvanised cross clamp with a parts list.

Download the exploded view (PDF)

Conductor grooves

Each plate has a pressed round groove at its centre, running at 45 degrees from one edge of the plate to the other. The groove has a 9 mm outer radius and projects 7 mm from the plate surface. When the two plates are fitted together, the grooves lie at right angles and each conductor sits in one of them. The KALOT name is engraved on the groove.

Galvanised cross clamp on the cross-shaped crossing of a round wire and a galvanised stranded wire.

Galvanised cross clamp, round wire to round wire

Drag to rotate; scroll to zoom.Open full screen

Frequently Asked Questions

What is a galvanised cross clamp and what is it used for?

A galvanised cross clamp is a pressed galvanised steel part that joins two round galvanised conductors where they cross, in an X shape. Two identical plates with diagonal grooves fit over the crossing, and two M6 bolts press the conductors together. It is used most often at the crossings and branches of galvanised round wire in foundation earthing.

Does a galvanised cross clamp differ from what is sold as a galvanised four-way clamp or a cross clamp?

There is no difference: these are all names for the same part. On the market it is also called a "galvanised four-way clamp", a "cross clamp" or a "round wire to round wire clamp", because it joins two round conductors in a four-way or three-way arrangement.

Which round wire and conductor sizes does the galvanised cross clamp suit?

Code GLSC 5095 clamps round galvanised conductors from 50 to 95 mm²: that means 8 to 11 mm round wire, or 50, 70 and 95 mm² stranded conductor. Both the 10 mm round wire common in foundation electrodes and the 8 mm round wire used on roof networks fall within this range. If your conductor sizes sit at the edge of the range, our specialists will recommend the right clamp.

Can I join two conductors of different sizes with one cross clamp?

Yes, as long as both conductors are round and galvanised and each has a cross-section between 50 and 95 mm²: for example a 10 mm round wire with a 95 mm² stranded conductor. Each conductor sits in the groove of its own plate, and the two plates press them together.

Is the galvanised cross clamp suitable for copper conductors too?

No. Do not use galvanised parts next to copper. In the presence of moisture, contact between zinc and copper uses up the galvanised coating faster. For stranded copper conductors, use our four-way conductor-to-conductor clamp.

Can a galvanised cross clamp be cast inside foundation concrete?

Yes, that is its main use. Before pouring concrete, check all the crossings, photograph them and make sure at least 5 cm of concrete surrounds the clamp and conductors. Do not leave a galvanised connection in soil or at the boundary between concrete and soil; make connections that go underground permanent with exothermic welding. In coastal areas, or with saline soil and water, talk to our specialists before choosing galvanised parts.

Why not tie foundation round wire crossings with reinforcement tie wire?

Reinforcement tie wire is useful for holding the round wire in place, but lightning protection standards do not consider it suitable for carrying lightning current and prefer a clamped or welded connection. The cross clamp makes a firm bolted connection with no welding or heat next to the reinforcing bars.

What is the code of the galvanised cross clamp, and what should we send for a price enquiry?

The code for this clamp is GLSC 5095, and it clamps round conductors from 50 to 95 mm². When you enquire, send us the material and size of both conductors (round wire diameter or stranded conductor cross-section), the joint type (four-way or three-way), the installation location and the quantity needed, and our specialists will confirm the right clamp and the price.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.