Move your pointer over the image to zoom in
Complete Product Overview
U clamp for connecting vertical tape to earth rod and reinforcing bar
Last updated:
The KALOT Group U clamp for vertical tape connects copper tape to an earth rod or reinforcing bar, in line with it, without drilling the tape. The U-bolt loops around the earth rod or bar and the earth rod sits on the upper plate; the tape, vertical and parallel to the earth rod, lies in the shallow groove of the lower plate, between the two brass plates. As the two nuts tighten, the tape is pressed between the plates and the upper plate grips the earth rod firmly. The result is a bolted joint you can open for inspection and measurement, then close again.
We made this clamp for places where a vertical tape, such as a down conductor of a lightning protection system coming down a wall or column, has to reach the top of an earth rod inside an earth inspection pit, or a reinforcing bar. Because the tape is not drilled, its cross-section stays complete. The body is brass, and the U-bolt and nuts are stainless steel with an M10 thread. Five codes, from UBDP 16 to UBDP 50, clamp an earth rod or reinforcing bar up to 16, 25, 31, 38 and 50 mm with 25 mm tape; for wire, see the U clamp for connecting conductor to earth rod.
Vertical tape on earth rods and reinforcing bars, with no drilling
To choose a code you need just two sizes: the diameter of the earth rod or reinforcing bar, and the tape width, which is 25 mm on every code.
- Vertical tape, in line with the earth rod
- No drilling of the tape
- Two-plate brass body, stainless steel U-bolt
- Earth rod or reinforcing bar up to 50 mm, in five codes
Tape between two plates, in line with the earth rod
The earth rod or reinforcing bar sits on the upper plate, and the tape, vertical and parallel to it, lies in the shallow groove of the lower plate between the two plates. Tightening the two nuts secures them both. The tape can run on through the clamp or end at this clamp.
No drilling of the tape
The tape is not drilled and keeps its full cross-section. The U-bolt does not rely on the earth rod's thread either, so it also fits unthreaded earth rods, earth rods with a damaged top and ribbed reinforcing bar.
Material: brass and stainless steel
The two plates are cast brass, and the U-bolt and nuts are stainless steel with an M10 thread.
Five UBDP codes and drawings
Vertical tape U clamp datasheet (PDF)The code table from UBDP 16 to UBDP 50, dimensional drawing, technical drawing, exploded view, installation schematic, connection modes and installation steps are all yours in the technical specifications tab, as PDF files, alongside the datasheet of this clamp.
Advice from KALOT Group specialists
With your enquiry, send us the diameter and material of the earth rod or reinforcing bar, the tape width and thickness and the quantity you need, and our specialists will suggest the right code. For ribbed reinforcing bar, give its nominal diameter.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Type | Two-plate U clamp for connecting vertical tape to an earth rod or reinforcing bar |
Body (two jaws) | Cast brass |
U-bolt and nuts | Stainless steel, M10 thread |
Conductor | Copper tape, 25 mm wide |
Maximum earth rod or reinforcing bar diameter | 16, 25, 31, 38 or 50 mm (depending on the code) |
Tape route | Vertical, in line with the earth rod; through-run or end connection |
Tape drilling | Not needed |
Matching earth rod | Copper, copper-bonded or stainless steel, threaded or unthreaded |
Connection type | Bolted, can be opened and refastened |
Typical installation location | Earth inspection pit; reinforcing bar of a column or foundation |
Codes | UBDP 16 to UBDP 50 (five codes) |
Vertical tape U clamp codes (UBDP)
Code | Maximum earth rod or reinforcing bar diameter (mm) | Tape width (mm) |
|---|---|---|
UBDP 16 | 16 | 25 |
UBDP 25 | 25 | 25 |
UBDP 31 | 31 | 25 |
UBDP 38 | 38 | 25 |
UBDP 50 | 50 | 25 |
Diameter and width are in millimetres; the number in each code is the largest earth rod or reinforcing bar diameter that clamp takes. Our products are continually improved and the dimensions of some may be updated; before you buy, please ask our specialists for the final dimensions.
Dimensional drawing
Download the dimensional drawing (PDF)
Technical drawing
Download the technical drawing (PDF)
Exploded view
Download the exploded view (PDF)
The two plates and the tape seat
The U-bolt loops around the earth rod or reinforcing bar and its two legs pass through the two brass plates. The earth rod sits on the upper plate; the lower plate has a shallow groove in its centre, as wide as the tape, and the tape, vertical and in line with the earth rod, lies in this groove between the two plates. Two nuts fasten onto the lower plate and, as they tighten, the lower plate presses the tape against the upper plate and the upper plate against the earth rod.
Click to view enlarged
Applications of the vertical tape U clamp
- Down conductor in an inspection pit: connecting the tape down conductor of a lightning protection system to the top of a copper-bonded earth rod inside a concrete or polyethylene earth inspection pit, where the joint stays accessible for inspection and measurement
- Vertical tape on a wall or column: connecting tape that comes down a wall or column to an earth rod or reinforcing bar, in line with it and without bending the tape
- Reinforcement bonding: connecting copper tape to the reinforcing bar of a column or foundation, before the concrete is poured or at a connection point that stays accessible, for bonding the structure to the earthing system
- Unthreaded or damaged earth rods: connecting tape to copper or stainless steel earth rods, unthreaded earth rods and earth rods whose top was damaged during driving
Installation schematic
Download the execution schematic (PDF)
Connection modes
Download connection modes (PDF)
Installation steps for the vertical tape U clamp
- Choose the clamp code from the code table by the diameter of the earth rod or reinforcing bar; the diameter must not exceed the number in the code, and the tape width is 25 mm.
- Before installation, clean paint, rust, mud and any non-conductive layer from the contact surfaces of the earth rod or reinforcing bar and the tape.
- Undo the nuts and the lower plate, and place the U-bolt around the earth rod or reinforcing bar so that the earth rod sits on the upper plate.
- Lay the tape on the upper plate, vertical and in line with the earth rod, fit the lower plate so the tape seats in its groove, and first tighten the nuts by hand.
- Tighten the nuts with a spanner, evenly and in turn, according to the manufacturer's instructions, until the tape is fully pressed between the two plates and the clamp sits firmly on the earth rod.
- Check that the tape sits straight and untwisted in the groove, that the two plates lie parallel to each other and that the clamp has not damaged the earth rod, reinforcing bar or tape.
Download the installation steps (PDF)
Installation tools
All you need for installation is one spanner that fits the nuts; this joint needs no drilling, heat, electricity or mould.
Inspection and measurement
During periodic inspections, look at the condition of the clamp, U-bolt and tape inside the earth inspection pit and check for corrosion, movement and loosening. If the joint has loosened, corroded or been damaged, open it, clean the contact surfaces and close it again according to the manufacturer's instructions, or replace the clamp. For measuring the earth termination resistance, open the joint with a spanner to separate the earth rod from the tape, and close it after the measurement.
Choosing a size and asking for a price on the vertical tape U clamp
With your enquiry, send us the diameter and material of the earth rod or reinforcing bar, the tape width and thickness and the quantity you need, and our specialists will suggest the right code. For ribbed reinforcing bar, give its nominal diameter.
Click to view enlarged
Choose this clamp when a vertical copper tape has to be fixed in line with an earth rod or reinforcing bar and you do not want to drill the tape. The tape is held between two plates and its cross-section stays intact; the U-bolt loops around the earth rod and does not rely on a thread, so it can be fitted anywhere along the earth rod or reinforcing bar. For a tape down conductor arriving vertically at the pit, this is the most natural connection route. Our brass U clamp is for copper tape and wire; for a galvanised conductor or reinforcing bar, we recommend the galvanised U clamp.
Advantages of the vertical tape U clamp
- No drilling of the tape: the tape is held between two plates and keeps its full cross-section; installation is also quick, with no drill.
- In line with the earth rod: the vertical tape reaches the clamp beside the earth rod with no bend, the natural route of a down conductor.
- On ribbed reinforcing bar and unthreaded earth rods: the U-bolt closes around the earth rod or bar and needs no thread or flat top.
- Five sizes up to 50 mm: from a 16 mm earth rod to a 50 mm reinforcing bar, with a single tape width.
- Can be opened and closed: for inspection, resistance measurement or rerouting the tape, you undo the nuts and tighten them again.
Vertical tape U clamp or A-type clamp?
Feature | Vertical tape U clamp | A-type clamp |
|---|---|---|
What it connects | Tape to earth rod or reinforcing bar | Tape to earth rod |
Tape route | Vertical, in line with the earth rod | Horizontal, on top of the earth rod |
Fastening point | Anywhere along the earth rod or reinforcing bar | Top of the earth rod |
Earth rod or reinforcing bar diameter (mm) | Up to 16, 25, 31, 38 or 50 | Up to 16, 20 or 25 |
Tape width (mm) | 25 | 25, 30 or 50 |
Fixing method | U-bolt, two jaws, two nuts | One piece, one bolt |
Both clamps connect tape to an earth rod without drilling, and both belong at accessible points such as an earth inspection pit. If the tape comes down vertically beside the earth rod or the joint is on a reinforcing bar, choose this clamp; if the tape reaches the top of the earth rod horizontally, choose the A-type clamp. For joints buried in soil, we recommend exothermic welding.
If these conditions apply to you, see these clamps as well
Clamp | When |
|---|---|
When the tape reaches the top of the earth rod horizontally. | |
U clamp for connecting conductor to earth rod and reinforcing bar | When the conductor is a wire, not a tape. |
Three-piece U clamp for connecting two conductors to earth rod and reinforcing bar | When you are fixing two wires to one earth rod with a single clamp. |
Galvanised U clamp for connecting conductor to earth rod or reinforcing bar | When the conductor or reinforcing bar is galvanised. |
When you are sourcing the copper tape itself for the down conductor or earthing system. | |
Reinforcing bar bonding plate with conductor for concrete structures | When the reinforcement of a concrete structure needs a brass connection point for the earthing system. |
Compare all our earthing clamps in the "Which clamp should we choose?" table.
The KALOT Group U clamp is designed and made in line with IEC 62561-1, the standard that sets the requirements for lightning protection system connection components, including clamps.
IEC 60364-5-54 accepts connecting an earth conductor to an earth electrode with a suitable clamp or mechanical connector, alongside exothermic welding and compression joints, provided the clamp is installed following the manufacturer's instructions and does not damage the electrode or conductor.
IEC 62305-3 treats clamping as one of the accepted connection methods in a lightning protection system. It also recommends a test joint where the down conductor meets the earthing system, which can be opened with a tool for measurement and stays closed in normal use.
In Iran, Part Thirteen of the National Building Regulations places the top of the earth rod of a simple earth electrode inside a covered pit and accepts its connection to the earthing conductor by a dedicated clamp or by welding. The same part requires the clamp, earth rod and conductor materials to be compatible, and connections to be checked for tightness and corrosion during periodic inspections. The Earthing System Safety Code also requires the connection material to be compatible with the electrode and conductor. To learn more, see standards for the design and installation of earthing systems.
U clamp for connecting vertical tape to earth rod and reinforcing bar
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
- Dimensional drawing of the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
- Technical drawing of the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
- Exploded view of the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
- Installation schematic of the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
- Connection modes of the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
- Installation steps for the U clamp for connecting vertical tape to earth rod and reinforcing barLanguage: Persian (opens in a new tab)
Frequently Asked Questions
What is the vertical tape U clamp and what does it do?
The vertical tape U clamp is a brass fitting with a U-bolt that fixes copper tape in line with an earth rod or reinforcing bar. The U-bolt loops around the earth rod, the tape sits between the two plates and two nuts press them together. The tape is not drilled, and the joint can be opened for inspection.
Why not drill the tape?
Every hole reduces the cross-section of the tape, and drilling on site also calls for a drill and a power supply. With this clamp the tape is held between two plates and its cross-section stays intact.
How do we choose the code of a vertical tape U clamp?
The number in each code is the largest earth rod or reinforcing bar diameter the clamp takes: UBDP 16 for a 16 mm earth rod, UBDP 38 for a 32 mm reinforcing bar and UBDP 50 for a 50 mm reinforcing bar. Tape width is 25 mm on every code. For borderline sizes, our specialists will suggest the right code.
What should we do for tape wider than 25 mm?
The codes of this clamp are for 25 mm tape. If your tape is wider and reaches the top of the earth rod, see the A-type clamp for 30 and 50 mm tape; otherwise, send us the tape size with your enquiry and our specialists will suggest a suitable clamp.
Can the vertical tape U clamp also be fitted on ribbed reinforcing bar?
Yes. The U-bolt loops around the ribbed reinforcing bar, which sits on the upper plate, and the tape is clamped between the two plates in line with the bar. Choose the code by the bar diameter, and make the joint before the concrete is poured or at a point that stays accessible for inspection.
Can this clamp also be used with galvanised tape or a galvanised earth rod?
No. Our brass U clamp is for copper, copper-bonded or stainless steel tape and earth rods; galvanised steel in contact with copper and brass may suffer galvanic corrosion. For galvanised conductors, go through the galvanised U clamp with our specialists; in soil and inside an earth pit, copper, whether plain or tinned, is not connected to galvanised parts.
Should the joint go inside the earth inspection pit or under the soil?
This clamp belongs at accessible points, such as a concrete or polyethylene earth inspection pit, so you can see it, open it for measurements and close it again. Make connections that go underground permanent with exothermic welding.
What is the vertical tape U clamp made of?
The two plates are cast brass, and the U-bolt and nuts are stainless steel with an M10 thread.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.