Move your pointer over the image to zoom in
Complete Product Overview
Brass reinforcing bar bonding plate for concrete structures
Last updated:
Our brass reinforcing bar bonding plate creates a fixed earth connection point on the face of a concrete column or wall, connected at the back to the reinforcing bar. The plate stays flush with the concrete, and the earth or bonding conductor is fixed with a cable lug on its M10 bolt. Inside the concrete, a copper conductor is exothermically welded to the stem behind the plate and clamped to the reinforcing bar.
We make the plate in three brass models: one-hole horizontal and vertical with an 80 × 40 mm plate, and two-hole with a 70 × 40 mm plate for connecting two conductors. To learn about bonding and foundation earthing, read our related articles.
Access to the reinforcing bar from the concrete face
The bonding plate is mounted on the formwork before the pour and connected to the reinforcing bar. After the pour, the earth or bonding conductor is bolted to it without breaking into the concrete.
- A fixed earth connection point on the concrete face
- One-piece cast brass
- One or two M10 holes for the cable lug
- Connects to reinforcing bar with a copper conductor
Flush with the concrete face
The plate is fixed to the formwork and, once the formwork comes off, stays smooth and flush with the wall or column.
One or two connections
The one-hole model takes one conductor and the two-hole model takes two, for example to connect to the earth bar and the down conductor at the same time.
Material: brass
The plate and stem are one piece of cast brass, and brass is compatible with copper conductors and copper cable lugs.
Drawings and datasheet
Brass reinforcing bar bonding plate datasheet (PDF)You will find the dimensional drawing of the three models, technical drawing, exploded view, installation schematic, installation steps and three-dimensional view on this page and as a PDF, alongside the datasheet.
Advice from KALOT Group specialists
When you enquire, send us the model (one-hole or two-hole), number of points, structure type and conductor cross-section, and our specialists will also propose the right clamp, cable lug and conductor.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Type | Bonding plate (fixed earth connection point) for concrete structures |
Material | Cast brass, one piece |
Models | One-hole horizontal, one-hole vertical and two-hole |
Plate | 80 × 40 × 5 or 70 × 40 × 5 mm, with earth symbol and KALOT name |
Connection hole | M10, one or two |
Fixing hole | Two Ø3 holes on the one-hole model, for nailing to the formwork |
Stem | Tapered, behind the plate, inside the concrete |
Connection to reinforcing bar | Copper conductor, exothermically welded to the stem and U-clamped to the reinforcing bar |
External connection | Cable lug and M10 bolt |
Installation location | Surface of concrete columns, walls, foundations and beams |
Models and sizes
Model | Plate (mm) | Connection hole | Overall length L (mm) | Weight (g) |
|---|---|---|---|---|
One-hole horizontal | 80 × 40 × 5 | 1 × M10 | 55 | 291 |
One-hole vertical | 40 × 80 × 5 | 1 × M10 | 55 | 291 |
Two-hole | 70 × 40 × 5 | 2 × M10 | 40 | 322 |
Sizes are in millimetres and weight in grams. On the one-hole model the M10 thread runs right through to the end of the stem. On the two-hole model each thread on the face is about 22 mm deep, and the end of the stem also has an M10 thread about 33 mm deep. Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before you buy.
Dimensional drawing
Download the dimensional drawing (PDF)
Technical drawing
Download the technical drawing (PDF)
Exploded view
Download the exploded view (PDF)
Plate structure
The bonding plate is one piece of cast brass: a plate that stays flush with the concrete face, and a tapered stem behind it that sits inside the concrete. The M10 threaded hole on the face of the plate takes the bolt for the external conductor's cable lug; on the one-hole model this thread runs right through to the end of the stem. Inside the concrete, a copper conductor is exothermically welded to the end of the stem and its other end is fixed to the reinforcing bar. The two-hole model also has an M10 thread at the end of the stem.
Click to view enlarged
Applications of the reinforcing bar bonding plate
- Concrete columns and walls: a bonding point connecting the reinforcement in columns and walls to the earth bar and the building's main bonding.
- Foundations and basement walls: an outlet on the wall for the foundation earth electrode and foundation reinforcement, for connection to the earth bar and for measurement.
- Lightning protection down conductor: connects the down conductor of the lightning protection system to the column reinforcing bar. The two-hole model allows two conductors to connect at the same time.
- Electrical and plant rooms: bonding points for equipment and metal enclosures on the concrete walls of electrical rooms and plant rooms.
Installation schematic
Download the execution schematic (PDF)
Models
Download connection modes (PDF)
Bonding plate installation steps
- Before installation, join the copper bonding conductor to the end of the stem behind the plate by exothermic welding.
- Fix the plate to the inner face of the formwork: the one-hole model with nails through its two fixing holes, the two-hole model with an M10 bolt passed through a hole in the formwork into its thread. Seal the threaded holes with a cap or tape so that concrete slurry cannot get in.
- Run the conductor to the nearest reinforcing bar and fix it with a U clamp for connecting conductor to earth rod and reinforcing bar. The concrete cover over the conductor and clamp must be complete.
- After the pour and once the formwork comes off, remove the cap. The plate stays flush with the concrete face.
- Fix the external conductor's cable lug to the plate with an M10 bolt and washer, and tighten the bolt according to the manufacturer's instructions.
- Measure the electrical continuity between the plate and the reinforcing bar or earth bar, and record the result.
Download the installation steps (PDF)
Installation tools
Installation needs a graphite mould and exothermic weld powder to join the conductor to the stem, a hammer and nails or a bolt for the concrete formwork, and a spanner for the clamp and the cable lug bolt.
Checks and measurement
Before the pour, check that the plate is firm on the formwork and that the weld and the conductor clamp on the reinforcing bar are sound. After the pour, measure the electrical continuity between the plates and the earth bar with a low-resistance ohmmeter and record the result. See also our article on earth resistance measurement.
Selection and price enquiry
For a price on the bonding plate, send our specialists the model (one-hole horizontal, vertical or two-hole), quantity, structure type and conductor cross-section. If you want the plate with a ready-fitted conductor, see the reinforcing bar bonding plate with conductor.
Click to view enlarged
In a concrete building, the reinforcing bar can be part of the earthing and bonding system, provided it is reliably connected, but after the pour it is out of reach. The bonding plate connects to the reinforcing bar before the pour and leaves a connection point on the concrete face, so the earth or bonding conductor can be bolted to it whenever needed, without breaking into the concrete.
Advantages of the brass bonding plate
- No breaking into concrete: the connection to the reinforcement is made before the concrete is poured.
- One-piece brass: the plate and stem are a single casting and are compatible with copper.
- Flush and neat: the plate is fixed to the formwork and stays smooth on the wall.
- One or two connections: the two-hole model takes two conductors separately.
- Easy to inspect: the cable lug bolts on and off.
Brass plate or stainless steel bonding point?
Feature | Brass bonding plate | Stainless steel bonding point |
|---|---|---|
Material | Cast brass | Stainless steel |
Plate shape | Rectangular, 80 × 40 or 70 × 40 | Round, diameter 80 |
Connection to reinforcing bar | Copper conductor, exothermic welding and U clamp | Steel bar behind the plate and U clamp |
External connection | One or two M10 bolts | One M10 × 1.25 bolt |
For a weld-free connection with a steel bar, see the stainless steel bonding point, and for a plate with a factory-fitted conductor, see the reinforcing bar bonding plate with conductor.
If this matches your situation, see these products too
Product | When |
|---|---|
U clamp for connecting conductor to earth rod and reinforcing bar | For fixing the copper conductor to the reinforcing bar. |
When you want a ready-made conductor, fitted at the factory. | |
When you want a weld-free connection using a steel bar. | |
The bonding conductor inside the concrete. | |
For the end of the external conductor. | |
For gathering bonding conductors together. |
Compare all earthing and bonding clamps in the "Which clamp should we choose?" table.
The KALOT Group bonding plate is designed and made in accordance with IEC 62561-1, the standard that sets the requirements for connection components of a lightning protection system, including its earthing system.
IEC 62305-3 treats the reinforcement of a concrete structure, provided it is electrically continuous, as a natural component of the lightning protection system and requires it to be connected to the earthing system. IEC 60364-5-54 also recognises foundation reinforcement (except in prestressed concrete), when reliably connected, as an earth electrode.
Part Thirteen of the National Building Regulations requires main bonding in all buildings and lists the steel reinforcing bars inside reinforced concrete among the types of earth electrode.
The location of the connection points, the conductor cross-sections and the connection method are decided by the earthing system designer. To learn more, see standards for the design and installation of earthing systems.
Three-dimensional view of bonding plate installation
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
- Brass reinforcing bar bonding plate dimensional drawingLanguage: Persian (opens in a new tab)
- Brass reinforcing bar bonding plate technical drawingLanguage: Persian (opens in a new tab)
- Brass reinforcing bar bonding plate exploded viewLanguage: Persian (opens in a new tab)
- Brass reinforcing bar bonding plate installation schematicLanguage: Persian (opens in a new tab)
- Brass reinforcing bar bonding plate connection modesLanguage: Persian (opens in a new tab)
- Brass reinforcing bar bonding plate installation stepsLanguage: Persian (opens in a new tab)
Frequently Asked Questions
What is a reinforcing bar bonding plate?
It is a brass part that sits flush on the face of a concrete column or wall and connects at the back to the reinforcing bar inside the concrete. The earth or bonding conductor is fixed with a cable lug on its M10 bolt, connecting the structural reinforcing bar to the earthing system without breaking into the concrete.
Which models of bonding plate does KALOT Group offer?
Three brass models: one-hole horizontal with an 80 × 40 plate, one-hole vertical with a 40 × 80 plate, and two-hole with a 70 × 40 mm plate. The plate is 5 mm thick and the connection thread is M10.
How does the plate connect to the reinforcing bar?
A copper conductor is joined by exothermic welding to the end of the stem behind the plate, and its other end is fixed to the reinforcing bar with a brass U clamp.
How is the bonding plate installed?
Once the conductor is welded to the stem, the plate is fixed to the inner face of the formwork (the one-hole model with nails, the two-hole model with an M10 bolt from behind the formwork) and the threaded hole is sealed. The conductor is then clamped to the reinforcing bar and the concrete is poured. When the formwork comes off, the plate stays flush with the concrete and the cable lug is bolted onto it.
One-hole or two-hole model?
For one external conductor, the one-hole model is enough. When two conductors, such as the earth bar conductor and the lightning protection down conductor, must connect at one point, choose the two-hole model.
How does the brass plate differ from the stainless steel bonding point?
The brass plate connects to the reinforcing bar with a copper conductor and exothermic welding, and has one or two connection bolts. The stainless steel bonding point has a round plate and a steel bar that connects to the reinforcing bar with a U clamp and no welding.
What size is the cable lug bolt?
M10. Use a stainless steel bolt and washer, and tighten the bolt according to the manufacturer's instructions.
What checks are needed after the concrete is poured?
Remove the threaded hole cover, check the thread is clean, and measure the electrical continuity between the plate and the reinforcing bar or earth bar with a low-resistance ohmmeter, then record the result.
What information should we send for a quote?
Send us the model, quantity, structure type and conductor cross-section, and our specialists will propose the clamp, cable lug, conductor and price.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.