KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original
Earthing and bonding clamps

Complete Product Overview

Foundation earthing and bonding clamp (SBRC 2030)

Last updated:

Our foundation earthing and bonding clamp (code SBRC 2030) fixes the foundation earth electrode conductor, whether round wire, tape or copper conductor, to the foundation reinforcing bar before the pour. The clamp consists of two pressed steel parts: a frame that sits on the reinforcing bar and a pressure jaw that presses the conductor onto the bar as its single M10 bolt is tightened.

You can fix the conductor in line with the reinforcing bar (parallel, II) or at right angles to it (cross, +). The clamp takes 20 to 32 mm reinforcing bar with 6 to 10 mm round conductor or 40 mm tape. To learn about the method and its design, read our article Earthing systems based on foundation earthing.

Connecting the electrode conductor to foundation reinforcing bar

Choose the clamp by reinforcing bar diameter and conductor type: the SBRC 2030 is made for 20 to 32 mm reinforcing bar and fixes round conductor, tape or copper conductor to it, parallel or cross.

  • Connects the earth conductor to foundation reinforcing bar before the pour
  • Parallel (II) and cross (+) connection with one clamp
  • Round conductor 6 to 10 mm, 40 mm tape or copper conductor
  • Two pressed steel parts and one M10 bolt
  • Quick installation with one screw

    The frame sits on the reinforcing bar from above and the conductor goes under the pressure jaw. To close it, simply tighten one M10 bolt with a spanner. No welding, power or mould needed.

  • Six connection modes

    You can clamp round conductor, copper conductor or tape to the reinforcing bar, parallel or cross. This one clamp handles all of these modes.

  • Material: steel

    The frame and pressure jaw are made from pressed steel sheet and the M10 × 45 bolt from steel. The clamp sits next to the steel reinforcing bar, protected by the concrete.

  • SBRC 2030 drawings and datasheet

    You will find the dimensional drawing, technical drawing, exploded view, installation schematic, six connection modes and installation steps in the Technical Specifications tab and as a PDF, alongside the datasheet for this clamp.

    Foundation earthing and bonding clamp datasheet (PDF)
  • Advice from KALOT Group specialists

    When you enquire, send us the reinforcing bar diameter, the conductor type and size (round wire, tape or copper conductor) and the electrode length or number of connections, and our specialists will propose the number of clamps and the items you need.

Technical Product Information

Click to view enlarged

Feature

Value

Type

Bolted clamp connecting the earth conductor to reinforcing bar, for foundation earthing and bonding

Code

⁦SBRC 2030⁩

Frame and pressure jaw material

Pressed steel sheet

Bolt

M10 × 45, steel

Reinforcing bar

Diameter 20 to 32 mm

Round conductor (round wire or reinforcing bar)

Diameter 6 to 10 mm

Flat conductor (tape)

Width 40 mm, thickness 4 to 5 mm

Copper conductor

Stranded copper conductor; state the cross-section when enquiring

Connection mode

Parallel (II) and cross (+)

Dimensions (W × H × D)

⁦65 × 75 × 51 mm⁩

Weight

About 300 g

Installation location

On the reinforcing bar, inside the foundation concrete

SBRC 2030 sizes

Code

Reinforcing bar (mm)

Round conductor (mm)

Tape (mm)

⁦W × H × D (mm)⁩

Bolt

Weight (g)

⁦SBRC 2030⁩

⁦20-32⁩

⁦6-10⁩

⁦40 × 4-5⁩

⁦65 × 75 × 51⁩

⁦M10 × 45⁩

⁦300⁩

Sizes are in millimetres and weight in grams; the reinforcing bar and conductor figures are the diameter range the clamp takes. Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before you buy.

Dimensional drawing

Dimensional drawing of the SBRC 2030 foundation earthing and bonding clamp with a size table.

Download the dimensional drawing (PDF)

Overall clamp dimensions: 65 × 75 × 51 mm.

Technical drawing

Technical drawing of the foundation earthing and bonding clamp with three views.

Download the technical drawing (PDF)

Exploded view

Exploded view of the foundation earthing and bonding clamp with a parts list.

Download the exploded view (PDF)

Clamp structure and conductor position

The clamp frame is a U-shaped channel whose two sides are bent into a letter C, each with a V-shaped groove at the bottom where the reinforcing bar sits. The pressure jaw mounts on top of the frame, and its lower edge also has a V groove. Tightening the clamp's single bolt brings the jaw down and presses the conductor onto the reinforcing bar. Because both the bar and the conductor sit in V grooves, the connection stays in place in both parallel and cross modes. The code SBRC 2030 is engraved on top of the frame and the KALOT mark on the pressure jaw.

The clamp from six views: frame with C jaws, pressure jaw and M10 bolt.
The SBRC 2030 code is engraved on top of the frame.

Foundation earthing and bonding clamp

Drag to rotate; scroll to zoom.Open full screen

Frequently Asked Questions

What is a foundation bonding clamp, and which conductors does it connect to the reinforcing bar?

A foundation bonding clamp is a bolted part that fixes the earth electrode conductor or bonding conductor to the foundation reinforcing bar before the concrete is poured. Our SBRC 2030 clamp connects 6 to 10 mm round conductor (round wire or reinforcing bar), 40 mm tape and stranded copper conductor to 20 to 32 mm reinforcing bar.

Which reinforcing bar diameter and which tape and round wire sizes does the SBRC 2030 clamp suit?

It suits 20 to 32 mm reinforcing bar, 6 to 10 mm round conductor and 40 mm tape, 4 to 5 mm thick. The design drawing and the standards set the electrode conductor size. For thinner reinforcing bar, see our clamp for connecting galvanised round wire to reinforcing bar.

What is the difference between a parallel (II) and a cross (+) connection?

In a parallel connection, the conductor runs in line with the reinforcing bar and is clamped on top of it, which suits a lengthwise electrode run along one bar. In a cross connection, the conductor passes over the reinforcing bar at right angles and is clamped at the crossing. The SBRC 2030 clamp makes both connections with the same part.

How often should the foundation electrode conductor be clamped to the reinforcing bar?

The design drawing sets the spacing. DIN 18014 gives a maximum of 2 metres, and the "Guideline for the Design and Implementation of Bonding in Buildings" from Iran's Construction Engineering Organisation calls for copper bonding conductors to be connected to the reinforcing bar at least every 6 metres, by welding or a suitable bolted clamp.

Is foundation bonding better done with a clamp or by welding?

Both methods are accepted. A bolted clamp installs quickly with no welding and suits connections inside concrete, while welding onto reinforcing bar needs the structural engineer's approval. For connections buried in soil, choose exothermic welding.

Can stranded copper conductor also be fixed to reinforcing bar with this clamp?

Yes. You can clamp stranded copper conductor to the reinforcing bar with the SBRC 2030, parallel or cross. Tell us the conductor cross-section when you enquire, and our specialists will confirm the clamp is suitable.

Can reinforcement tie wire replace the clamp?

No. Tie wire only holds the conductor in position on the reinforcing bar and does not make a stable electrical connection. The electrode conductor must be connected to the reinforcing bar with a bolted clamp or a weld.

How do we check the clamp connections before the concrete pour?

Check that all clamps are tight, that the electrode ring is continuous and that the branches are in the right place. Measure the electrical continuity between connection points with a test instrument and record the results. The conductor and clamp must be surrounded by concrete on every side.

What should we send for a price enquiry, and how many clamps do we need?

Send us the reinforcing bar diameter, the conductor type and size, and the electrode length or number of connections. The number of clamps is the electrode length divided by the connection spacing, plus the connections for the internal network and branches. Our specialists will propose a list of items.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.