Our foundation earthing and bonding clamp (code SBRC 2030) fixes the foundation earth electrode conductor, whether round wire, tape or copper conductor, to the foundation reinforcing bar before the pour. The clamp consists of two pressed steel parts: a frame that sits on the reinforcing bar and a pressure jaw that presses the conductor onto the bar as its single M10 bolt is tightened.
You can fix the conductor in line with the reinforcing bar (parallel, II) or at right angles to it (cross, +). The clamp takes 20 to 32 mm reinforcing bar with 6 to 10 mm round conductor or 40 mm tape. To learn about the method and its design, read our article Earthing systems based on foundation earthing.
Connecting the electrode conductor to foundation reinforcing bar
Choose the clamp by reinforcing bar diameter and conductor type: the SBRC 2030 is made for 20 to 32 mm reinforcing bar and fixes round conductor, tape or copper conductor to it, parallel or cross.
- Connects the earth conductor to foundation reinforcing bar before the pour
- Parallel (II) and cross (+) connection with one clamp
- Round conductor 6 to 10 mm, 40 mm tape or copper conductor
- Two pressed steel parts and one M10 bolt
Quick installation with one screw
The frame sits on the reinforcing bar from above and the conductor goes under the pressure jaw. To close it, simply tighten one M10 bolt with a spanner. No welding, power or mould needed.
Six connection modes
You can clamp round conductor, copper conductor or tape to the reinforcing bar, parallel or cross. This one clamp handles all of these modes.
Material: steel
The frame and pressure jaw are made from pressed steel sheet and the M10 × 45 bolt from steel. The clamp sits next to the steel reinforcing bar, protected by the concrete.
SBRC 2030 drawings and datasheet
Foundation earthing and bonding clamp datasheet (PDF)You will find the dimensional drawing, technical drawing, exploded view, installation schematic, six connection modes and installation steps in the Technical Specifications tab and as a PDF, alongside the datasheet for this clamp.
Advice from KALOT Group specialists
When you enquire, send us the reinforcing bar diameter, the conductor type and size (round wire, tape or copper conductor) and the electrode length or number of connections, and our specialists will propose the number of clamps and the items you need.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Type | Bolted clamp connecting the earth conductor to reinforcing bar, for foundation earthing and bonding |
Code | SBRC 2030 |
Frame and pressure jaw material | Pressed steel sheet |
Bolt | M10 × 45, steel |
Reinforcing bar | Diameter 20 to 32 mm |
Round conductor (round wire or reinforcing bar) | Diameter 6 to 10 mm |
Flat conductor (tape) | Width 40 mm, thickness 4 to 5 mm |
Copper conductor | Stranded copper conductor; state the cross-section when enquiring |
Connection mode | Parallel (II) and cross (+) |
Dimensions (W × H × D) | 65 × 75 × 51 mm |
Weight | About 300 g |
Installation location | On the reinforcing bar, inside the foundation concrete |
SBRC 2030 sizes
Code | Reinforcing bar (mm) | Round conductor (mm) | Tape (mm) | W × H × D (mm) | Bolt | Weight (g) |
|---|---|---|---|---|---|---|
SBRC 2030 | 20-32 | 6-10 | 40 × 4-5 | 65 × 75 × 51 | M10 × 45 | 300 |
Sizes are in millimetres and weight in grams; the reinforcing bar and conductor figures are the diameter range the clamp takes. Our products are continually improved and some dimensions may be updated, so please confirm final dimensions with our specialists before you buy.
Dimensional drawing
Download the dimensional drawing (PDF)
Technical drawing
Download the technical drawing (PDF)
Exploded view
Download the exploded view (PDF)
Clamp structure and conductor position
The clamp frame is a U-shaped channel whose two sides are bent into a letter C, each with a V-shaped groove at the bottom where the reinforcing bar sits. The pressure jaw mounts on top of the frame, and its lower edge also has a V groove. Tightening the clamp's single bolt brings the jaw down and presses the conductor onto the reinforcing bar. Because both the bar and the conductor sit in V grooves, the connection stays in place in both parallel and cross modes. The code SBRC 2030 is engraved on top of the frame and the KALOT mark on the pressure jaw.
Click to view enlarged
Applications of the foundation bonding clamp
- Foundation earth electrode: connects the ring or mesh of foundation earth electrode conductor (round wire or tape) to the reinforcing bar in the foundation base, at the spacing set by the design drawing. The method is explained in our article on foundation earthing.
- Structural reinforcing bar bonding: connects the bonding conductor to the reinforcing bar in foundations, tie beams and concrete columns, bringing the structural reinforcement into the building's main equipotential bonding.
- Branch from the foundation: connects a branch conductor to the reinforcing bar to bring the connection out towards the earth bar, the lightning protection down conductor or a measuring point.
- Copper conductor on reinforcing bar: connects stranded copper conductor to reinforcing bar inside concrete, parallel or cross.
Installation schematic
Download the execution schematic (PDF)
Connection modes
Download connection modes (PDF)
Installation steps for the foundation bonding clamp
- Choose the clamp by reinforcing bar diameter and conductor type: 20 to 32 mm reinforcing bar, 6 to 10 mm round conductor or 40 mm tape.
- Mark the connection points on the reinforcing bar according to the design drawing, and clean mud, concrete slurry and loose rust off the contact faces of the bar and conductor.
- Loosen the bolt and place the clamp frame on the reinforcing bar from above, so the bar sits in the V groove at the bottom of the jaws.
- Place the conductor parallel or at right angles to the reinforcing bar, on top of the bar and under the pressure jaw.
- Tighten the bolt with a spanner according to the manufacturer's instructions, until the conductor is pressed fully onto the reinforcing bar.
- Before the pour, inspect all connections, measure the electrical continuity of the electrode and branches, and record the results.
Download the installation steps (PDF)
Installation tools
A spanner to fit the M10 bolt head is all you need for installation; this connection needs no welding, power or mould.
Checks before the pour
Before the pour, check that all clamps are tight, that the electrode ring is continuous and that the branches are in the right place, and measure the electrical continuity between connection points (earth resistance measurement). The conductor and clamp must be surrounded by concrete on every side. Reinforcement tie wire only holds the conductor in position and does not replace the clamp.
Choosing and pricing a foundation bonding clamp
For a price on the foundation earthing and bonding clamp, send our specialists the reinforcing bar diameter, the conductor type and size (round wire, tape or copper conductor) and the number of connections. The number of clamps is the electrode length divided by the connection spacing, plus the connections for the internal network and branches.
Click to view enlarged
In a concrete foundation, the reinforcing bar is itself part of the earthing system, provided the electrode conductor is connected to it firmly and reliably. Ordinary tie wire does not make a stable electrical connection and cannot be inspected after the pour, and welding onto reinforcing bar needs the structural engineer's approval. The bolted SBRC 2030 clamp makes this connection without welding, quickly and uniformly at every point.
Advantages of the foundation earthing and bonding clamp
- Fast installation: one M10 bolt and one spanner, with no welding and no power.
- Six connection modes: round conductor, copper conductor or tape, parallel or cross.
- Stable connection during the pour: the V groove holds the reinforcing bar and conductor in place.
- Same material as the reinforcing bar: a steel clamp next to steel reinforcing bar, protected by concrete.
- Economical in large numbers: every foundation needs dozens of connections, and each one takes a single clamp and a few minutes' work.
Foundation bonding clamp or welding?
Feature | SBRC 2030 foundation bonding clamp | exothermic welding |
|---|---|---|
Connection type | Bolted, mechanical | Permanent weld |
Tools | One spanner | Mould, weld powder and igniter |
Connection to reinforcing bar | No welding, so no weld approval needed on the reinforcing bar | Weld on the reinforcing bar with the structural engineer's approval |
Best location | Inside foundation concrete | Inside concrete and connections buried in soil |
For connections buried in soil and for a permanent connection without bolts, choose exothermic welding.
If this matches your situation, see these products too
Product | When |
|---|---|
Clamp for connecting galvanised round wire to reinforcing bar | When you are connecting galvanised round wire to thinner reinforcing bar. |
Galvanised clamp for connecting tape to earth rod and round wire | When you are clamping galvanised tape to an earth rod or round wire. |
Galvanised U clamp for connecting conductor to earth rod or reinforcing bar | When you are fixing round wire or conductor to reinforcing bar or an earth rod with a U clamp. |
When you want the earth connection point on the concrete surface. | |
The usual conductor for a foundation earth electrode. | |
When the connection is buried in soil. |
Compare all earthing and bonding clamps in the "Which clamp should we choose?" table.
We design and manufacture the KALOT Group foundation earthing and bonding clamp based on IEC 62561-1, the standard that sets the requirements for connection components of lightning protection and earthing systems, including clamps.
The design of foundation earth electrodes and the use of reinforcing bar in the earthing system are covered in standards such as IEC 62305-3, IEC 60364-5-54 and DIN 18014. DIN 18014 gives a maximum of 2 metres for the spacing between electrode conductor connections to the reinforcing bar, and at least 5 cm of concrete cover around the conductor.
Topic Thirteen of the Iranian National Building Regulations treats foundation reinforcing bar as a component of the building's main equipotential bonding. The "Guideline for the Design and Implementation of Bonding in Buildings" from Iran's Construction Engineering Organisation (first edition, 1394) calls for copper bonding conductors to be connected to the structural reinforcing bar at least every 6 metres, by welding or a suitable bolted clamp.
The earthing system designer sets the connection spacing, conductor size and branch positions based on these standards and the project drawing. To learn more, see standards for designing and installing earthing systems.
Foundation earthing and bonding clamp
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
- Foundation earthing and bonding clamp dimensional drawingLanguage: Persian (opens in a new tab)
- Foundation earthing and bonding clamp technical drawingLanguage: Persian (opens in a new tab)
- Foundation earthing and bonding clamp exploded viewLanguage: Persian (opens in a new tab)
- Foundation earthing and bonding clamp installation schematicLanguage: Persian (opens in a new tab)
- Foundation earthing and bonding clamp connection modesLanguage: Persian (opens in a new tab)
- Foundation earthing and bonding clamp installation stepsLanguage: Persian (opens in a new tab)
Frequently Asked Questions
What is a foundation bonding clamp, and which conductors does it connect to the reinforcing bar?
A foundation bonding clamp is a bolted part that fixes the earth electrode conductor or bonding conductor to the foundation reinforcing bar before the concrete is poured. Our SBRC 2030 clamp connects 6 to 10 mm round conductor (round wire or reinforcing bar), 40 mm tape and stranded copper conductor to 20 to 32 mm reinforcing bar.
Which reinforcing bar diameter and which tape and round wire sizes does the SBRC 2030 clamp suit?
It suits 20 to 32 mm reinforcing bar, 6 to 10 mm round conductor and 40 mm tape, 4 to 5 mm thick. The design drawing and the standards set the electrode conductor size. For thinner reinforcing bar, see our clamp for connecting galvanised round wire to reinforcing bar.
What is the difference between a parallel (II) and a cross (+) connection?
In a parallel connection, the conductor runs in line with the reinforcing bar and is clamped on top of it, which suits a lengthwise electrode run along one bar. In a cross connection, the conductor passes over the reinforcing bar at right angles and is clamped at the crossing. The SBRC 2030 clamp makes both connections with the same part.
How often should the foundation electrode conductor be clamped to the reinforcing bar?
The design drawing sets the spacing. DIN 18014 gives a maximum of 2 metres, and the "Guideline for the Design and Implementation of Bonding in Buildings" from Iran's Construction Engineering Organisation calls for copper bonding conductors to be connected to the reinforcing bar at least every 6 metres, by welding or a suitable bolted clamp.
Is foundation bonding better done with a clamp or by welding?
Both methods are accepted. A bolted clamp installs quickly with no welding and suits connections inside concrete, while welding onto reinforcing bar needs the structural engineer's approval. For connections buried in soil, choose exothermic welding.
Can stranded copper conductor also be fixed to reinforcing bar with this clamp?
Yes. You can clamp stranded copper conductor to the reinforcing bar with the SBRC 2030, parallel or cross. Tell us the conductor cross-section when you enquire, and our specialists will confirm the clamp is suitable.
Can reinforcement tie wire replace the clamp?
No. Tie wire only holds the conductor in position on the reinforcing bar and does not make a stable electrical connection. The electrode conductor must be connected to the reinforcing bar with a bolted clamp or a weld.
How do we check the clamp connections before the concrete pour?
Check that all clamps are tight, that the electrode ring is continuous and that the branches are in the right place. Measure the electrical continuity between connection points with a test instrument and record the results. The conductor and clamp must be surrounded by concrete on every side.
What should we send for a price enquiry, and how many clamps do we need?
Send us the reinforcing bar diameter, the conductor type and size, and the electrode length or number of connections. The number of clamps is the electrode length divided by the connection spacing, plus the connections for the internal network and branches. Our specialists will propose a list of items.