The KALOT two-piece stainless steel clamp holds tape conductors on the wall. It is the part that keeps a tape down conductor in a lightning protection and earthing system flat and firm on the façade, from the roof edge to near ground level. It is made for tapes 20 to 30 wide and 2 to 3 mm thick and has two stainless steel parts: a base plate fixed to the wall with one screw and wall plug, and a formed cover that secures the tape with two M6 screws. The U slot at one end of the cover speeds up installation, especially at height. We make this clamp for façades that need to stay clean and secure for years.
Down conductor tape, flat and firm on the façade
A tape down conductor must stay fixed along its whole route, so that it does not move in the wind, leave its path or damage the façade. The KALOT two-piece stainless steel clamp secures the tape between the cover bridge and the base plate, and fixes to the wall with one screw and wall plug.
- Tape 20 to 30 mm wide, 2 to 3 thick
- Cover, base plate and screws in stainless steel
- Wall fixing with one screw and wall plug
- Cover with U-slot for quick installation
Two-piece construction
The base plate stays on the wall and the cover holds the tape. To inspect or replace the tape, only the cover comes off and the clamp's fixing to the wall stays untouched.
All stainless steel
The cover, base plate and screws are stainless steel, with no coating to scratch or fade over time, and well suited to building façades in all weather.
Press-formed M6 threads in the base plate
The cover screws go straight into the press-formed threads of the base plate, so all the work is done from the front of the façade, with no nut needed behind.
U-slot for work at height
The cover pivots on one screw and its U slot drops over the second screw from above. No screw is fully undone and the cover cannot be dropped during installation.
KALOT drawing and installation guide
Dimensional drawing, exploded view, installation steps and an installation schematic on a tape down conductor, as PDF and SVG for designers and installers.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Product type | Two-piece holding clamp for tape conductors on walls (down conductors and surface-run conductors) |
Suitable tape | Width 20 to 30 mm and thickness 2 to 3 mm, such as 25×2, 20×3, 25×3, 30×2 and 30×3 |
Material | Cover, base plate and screws in stainless steel |
Components | Formed cover + base plate with two press-formed M6 threads + two M6 pan-head cross-recess screws |
Cover and base plate dimensions | 60 × 20 mm; sheet thickness 1.5 mm |
Screw centre distance | 44 mm |
Cover bridge | Overall height 3 mm; tape channel 33 mm at the base and 21 mm at the top |
Wall fixing | One countersunk screw of up to 5 mm diameter and a wall plug, through the 5 × 8 mm slotted hole in the middle of the base plate |
Cover | Ø7 hole at one end, downward-facing U slot at the other |
Body weight (two parts, without screws) | 27 g |
Role in the system | Mechanical holder for tape; the electrical connection of conductors is made with connecting clamps |
Application | Down conductors and tape conductors of lightning protection, earthing and bonding systems on façades, walls and parapets |
Our products are continually improved and the dimensions and specifications of some may be updated. Please confirm them with our specialists before you buy.
Click to view enlarged
What is a tape-to-wall clamp and why is it needed?
The down conductor is the path lightning current takes from the air terminal on the roof to the earthing system, and it must stay straight, taut and on the shortest route down the façade along its whole length. Loose tape moves in the wind, knocks against the façade and can develop sharp bends or loops. A tape-to-wall clamp is installed at regular intervals along the conductor route and holds the tape by its wide face, flat and firm against the wall.
This clamp is a mechanical holder whose job is to keep the tape fixed on the surface. The electrical connection of two conductors, for example at a branch or a change of route, is made with connecting clamps such as the multi-purpose stainless steel four-way clamp or the two-way tape-to-tape clamp.
Choosing between KALOT tape-to-wall clamps
- Two-piece stainless steel clamp (this product): for tapes 20 to 30 mm wide and 2 to 3 thick; light, all stainless steel, with a slotted cover for quick installation.
- Two-piece brass clamp: cast brass body for 25×3 and 30×3 tape; two-piece brass clamp for fixing tape to walls
- One-piece clamp: a simple single-part holder for 25×3 and 30×3 tape; one-piece tape-to-wall clamp
For round conductors, choose the sister product to this clamp: the two-piece stainless steel clamp for fixing conductor to walls, with a grooved cover for 50 and 70 mm² conductors. If you are unsure about the choice of clamp or the spacing, our specialists at KALOT Group will gladly guide you.
Click to view enlarged
The drawing shows the front and side views of the cover and base plate and a section of the clamp installed on tape: length and width 60 × 20 mm, 1.5 mm sheet, 3 mm cover bridge height, 44 mm between screw centres, the Ø7 hole and U slot in the cover, and the M6 threads and 5 × 8 slotted hole in the base plate.
Download the drawing: PDF · SVG (vector)
Click to view enlarged
Clamp components
- Base plate: a 1.5 mm stainless steel strip, 60 mm long and 20 mm wide. In the middle is a countersunk slotted hole where the wall screw seats, allowing a little movement to adjust the alignment. At each end are press-formed M6 threads that take the cover screws directly, with no nut needed behind.
- Cover: a stainless steel sheet the same size as the base plate, with its centre formed into a low bridge under which the tape passes. One end of the cover has a hole and the other a downward-facing U slot.
- Two M6 pan-head cross-recess screws: they fix the cover to the base plate and press the tape between the cover bridge and the plate.
The cover bridge sits 1.5 mm from the base plate, which is less than the tape thickness. So when the screws are tightened, the cover presses down on the tape and locks it in place without drilling it.
Because the wall screw sits under the tape at the centre of the plate, opening and closing the cover does not disturb the clamp's fixing to the wall. To inspect or replace the tape, you open the cover and the base plate stays where it is.
The U slot makes installation simple: the cover swings up on the screw at the round-hole end, the tape goes underneath, and as the cover comes down the U slot drops over the second screw from above. No screw is fully undone and the cover stays on the wall as you work, so working from scaffolding or on ropes is quicker and less risky.
Which tapes fit this clamp?
This clamp is designed for tapes 20 to 30 mm wide and 2 to 3 mm thick, which covers the most common tape down conductor sizes, such as 25×2, 20×3, 25×3, 30×2 and 30×3.
KALOT stainless steel tape in 25×2 is the best partner for this clamp: with clamp and conductor in the same material, the result on the façade is clean and uniform. Copper tape and tinned copper tape in the same size range also install with this clamp.
Why stainless steel?
Down conductor clamps spend years exposed to rain, sun, pollution and façade moisture. The resistance of stainless steel lies in the metal itself, not in a coating that scratches or fades with time. It stays stable against atmospheric corrosion, and its bright finish looks clean and uniform on a building façade. The cover screws are stainless steel too.
Contact between copper or tinned copper tape and a stainless steel clamp is common in normal atmospheric conditions. In highly corrosive environments (industrial, coastal or chemical), or if the tape is aluminium or galvanised steel, please check material compatibility with the system designer and the technical specialists at KALOT Group before installation.
Click to view enlarged
Where it fits in the lightning protection system
This clamp is installed along the route of a tape down conductor, from the roof edge to the test joint near ground level, and on tape conductors on parapets and vertical surfaces. The roof conductor reaches the down conductor after passing the edge of the building, and the down conductor connects to the earthing system through the test joint.
Installation steps
- Mark the conductor route and the position of each clamp on the façade according to the system drawing.
- Drill the wall hole to suit the wall plug, clear out the dust and insert the plug. Choose the countersunk screw (up to 5 mm diameter) and wall plug to suit the wall material (concrete, brick, block).
- Set the base plate at right angles to the tape route and drive the screw through the central hole until its head seats in the countersink. The slotted hole lets you adjust the alignment of the plate slightly.
- Fix the cover loosely to the plate with the M6 screw at the round-hole end, and turn the second screw a few turns into the other thread.
- Swing the cover aside on the first screw and lay the tape on the plate, flat and free of twists.
- Bring the cover down over the tape until the U slot drops over the second screw from above.
- Tighten both screws gradually and evenly until the tape is firm in the clamp, without overtightening to the point of deforming the sheet.
- Finally, test the tape: it must not slip in the clamp and must stay straight in line with the clamps before and after. Up to a height of 2 m above ground, protect the down conductor against impact with a mechanical guard.
Clamp spacing along the tape route
The number and spacing of clamps are set by the system designer and depend on the type of system, the building height and wind conditions. Two references common on projects in Iran recommend the following:
System type and installation location | Clamp spacing |
|---|---|
ESE air terminal, down conductor (NF C 17-102) | Three clamps per metre (one clamp every 33 cm) |
Conventional system, down conductor up to a height of 20 m; common guidance based on IEC 62305-3 | Maximum 1 m |
Conventional system, down conductor above 20 m | Maximum 0.5 m |
Horizontal conductor on a roof, parapet or wall | Maximum 0.5 m |
In routine installations, a spacing of 30 to 50 cm between clamps is common; in ESE systems, do not exceed 33 cm. Closer spacing holds the tape more firmly on tall façades, in windy areas and where it is within reach or exposed to impact. Also fit a clamp before and after every bend or connecting clamp, and run the down conductor as straight and vertical as possible, with no loops or sharp bends.
Inspection and maintenance
During periodic inspections of the lightning protection system, check the clamps for loose screws, slack tape, movement of the base plate or mechanical damage, and retighten the screws evenly if needed. The electrical continuity of the down conductor is measured at the test joint (disconnector) near ground level.
Tape holding clamps for walls and roofs
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
- Dimensional drawing of the two-piece stainless steel clamp for fixing tape to walls (PDF)Language: Persian (opens in a new tab)
- Exploded view of the two-piece stainless steel clamp for fixing tape to walls (PDF)Language: Persian (opens in a new tab)
- Installation steps for the two-piece stainless steel clamp for fixing tape to walls (PDF)Language: Persian (opens in a new tab)
- Installation schematic on the tape down conductor of a lightning protection system (PDF)Language: Persian (opens in a new tab)
Frequently Asked Questions
Which tapes does this clamp suit?
For tapes 20 to 30 mm wide and 2 to 3 mm thick, such as 25×2, 20×3, 25×3, 30×2 and 30×3. KALOT stainless steel tape in 25×2 is the best partner for this clamp. For other sizes, please check with us before ordering.
Does this clamp connect two conductors together?
No. This clamp is a mechanical holder that keeps the tape in place on the wall. For the electrical connection of two conductors, use connecting clamps such as the multi-purpose stainless steel four-way clamp.
How far apart should the clamps be on a down conductor?
The final spacing is set by the system designer. In ESE systems, NF C 17-102 calls for three clamps per metre. In conventional systems, common guidance based on IEC 62305-3 for down conductors is a maximum of 1 m up to a height of 20 m and 0.5 m above that. In routine installations, a spacing of 30 to 50 cm is common.
What is the U-slot at one end of the cover for?
The cover pivots on the screw at the round-hole end, and the downward-facing U slot drops over the second screw from above, with no need to fully undo it. No screw comes out and the cover cannot be dropped during installation, so working at height becomes faster and safer.
How do we choose the wall screw and wall plug?
The base plate is fixed to the wall through the central hole with one countersunk screw of up to 5 mm diameter. Choose the screw and wall plug to suit the wall material (concrete, solid or hollow brick, block), preferably in a corrosion-resistant material so that they last as long as the clamp.
Can this clamp also be used with copper tape?
Yes. Contact between copper or tinned copper tape and a stainless steel clamp is common in normal atmospheric conditions. In highly corrosive environments, or for aluminium and galvanised tape, please check material compatibility with us before installation.
How does this clamp differ from the two-piece brass clamp and the one-piece tape-to-wall clamp?
All three hold tape on the wall. The two-piece stainless steel clamp is light, all stainless steel and quick to install thanks to its slotted cover. The two-piece brass clamp has a cast brass body, and the one-piece clamp is a simple single-part holder. The choice depends on the tape size, the conductor material and the project specification.
Is it also suitable for round conductors?
No. The cover bridge is designed for flat tape. For 50 and 70 mm² round conductors, use the KALOT two-piece stainless steel clamp for fixing conductor to walls.
Can it also be used on a roof?
This clamp installs on any firm surface that can take a screw and wall plug, such as façades, walls and parapets. On roofs with a waterproofing membrane, the conductor usually runs on roof support bases so that the membrane is not pierced.
Have a Technical Question?