Lightning protection and earthing for cement plants

A cement plant combines several features. The preheater tower and stack are the tallest structures in the area. Acidic stack gases corrode the conductors. Coal dust in the mill is explosive. Blasting takes place in the limestone quarry. And the large motors run on drives. Each of these has its own weak point in the earthing and lightning protection system. We have worked alongside clients at ten cement plants, from Mazandaran and Kurdistan to Khash and Lar.

The cement line, station by station

  1. Mine and blasting
  2. Crusher and conveyor belt
  3. Raw mill and silos
  4. Preheater tower, kiln and stack
  5. Coal mill and dust collector
  6. Cement mill and loading
  7. Substation, MCC and drives
  8. Control room and DCS
Station 1

Mine and blasting

A nearby lightning strike can set off detonators early. In mine safety records, this has been one of the main causes of premature blasts.

Our answer:
Use the Franklin France ACTIVE 4D ESE air terminal, which besides capturing lightning also warns of possible lightning from 30 km away. Earthing and bonding of the explosives store also greatly reduces the risk of this kind of damage, and a written procedure to stop blasting when a thunderstorm approaches helps a great deal as well.
Station 2

Crusher and conveyor belt

A long conveyor spreads its control cables and sensors along an open, extended route.

Our answer:
Bonding of the conveyor structure and control line surge protective devices at both ends of the route.
Station 3

Raw mill and silos

Tall concrete silos are not a reliable path for lightning current if their reinforcing bars are not continuous. Cement dust on substation insulators also forms a conductive layer with moisture, causing flashovers and outages.

Our answer:
Continuity testing of the reinforcing bars, and a separate down conductor where needed.
Station 4

Preheater tower, kiln and stack

The tallest point of the plant, with measuring instruments on top of the tower, is lightning's main target. In the stack, acidic vapour in the flue gas condenses on the wall and corrodes the lightning protection conductors and connections. A survey of a cement plant stack in Iran also found severe corrosion caused by acid gas condensation and sulphate deposits.

Our answer:
Risk assessment and lightning protection design, corrosion-resistant conductors and connections, KALweld® exothermic welding instead of bolted joints, bimetallic connections where dissimilar metals meet, and conductors, clamps and fittings in grade 316L stainless steel.
Station 5

Coal mill and dust collector

Dry coal dust hangs in the air inside the coal mill dust collector. Static electricity is a known ignition source in this area. Dust collector and coal mill explosions rank high in industrial insurers' loss statistics.

Our answer:
Bonding and earthing of all conductive parts, filter cages and ducts, plus SPDs suited to explosive atmosphere zones.
Station 6

Cement mill and loading

Large halls with steel structures and loading equipment that trucks stop right beside.

Our answer:
An integrated earthing network for the halls, and bonding of the structure with clamps and earth bars.
Station 7

Substation, MCC and drives

The large motors of fans and mills run on drives. Without low-impedance bonding, bearing currents groove the bearing surfaces and lead to early failure.

Our answer:
A high-frequency bonding network between motor, drive and earth terminal.
Station 8

Control room and DCS

Instruments at the top of the tower are wired to the control room through very long cables. A surge reaching these cables burns out DCS cards and shuts the kiln down.

Our answer:
Overvoltage protection design with Type 1 to 3 power SPDs and dedicated SPDs for data lines.

Reference: IEC 62305-2 and 3, NFPA 780 (industrial chimneys chapter), EN 60079-10-2 and 14, NFPA 77 and 654, IEC 62305-4

End of the journey: inspection

Dust, humidity, vibration and repeated plant expansions gradually wear down an earthing system that was sound on day one. Periodic inspection and earth resistance and continuity testing, carried out on a schedule with comparable reports, go a long way to solving this, and at KALOT we offer these services to our clients.

Plants we have worked with

Mazandaran Cement (Sari), Delijan Cement, Zaveh Cement, Kurdistan Cement (Sanandaj), Khash Cement, Larestan Cement (Lar), Ardabil Cement, Shahrekord Cement Industries, West Cement Industries (Kermanshah), Sirjan Cement, and a stone crushing and asphalt production plant in Tehran.

What to send for design and a quotation

Plant layout with the heights of towers, stacks and silos, a map of existing earth pits, a list of installed surge protective devices, the hazardous area classification of the coal mill, and the location of the mine's explosives store.

Frequently Asked Questions

Why does the lightning protection on a cement plant stack deteriorate so quickly?

Because acidic vapour in the flue gas condenses on the upper wall of the stack and corrodes the conductors and joints. The conductor material and connection type must be chosen for this environment.

Why does a coal mill need bonding?

Coal dust is explosive and static electricity is one of its ignition sources. All conductive parts must be connected to each other and to earth.

Does the lightning protection on the tower also protect the DCS?

No. Lightning protection safeguards the structure. DCS cards are protected by SPDs on power and instrumentation cables.