Tinned copper busbar (tin-coated copper busbar) in 4 m lengths
Order Code: TBCB 255–505
Last updated:
KALOT Group tinned copper busbar (tin-coated copper busbar) is a flat copper conductor with a tin coating in 4 m lengths. We use it where a copper bar or connection touches galvanised steel or aluminium in air, and for earth bars and bonding bars in damp electrical rooms. We supply it in three sizes: 25 × 5, 30 × 5 and 50 × 5 mm.
Copper busbar with a tin surface, for bars above ground
Use tinned copper busbar for bars and rigid connections that touch galvanised steel or aluminium in air, or that are installed in damp electrical rooms. Tinned busbar is for use above ground; in soil and concrete we recommend plain copper.
- 4 m length with tin coating
- Three sizes: 25 × 5, 30 × 5 and 50 × 5
- Contact with galvanised steel in air; bars and earth bars
- For use above ground
Tin facing galvanised steel
BS 7430 and national standard 4123 require copper conductors that touch or rest on galvanised steel to be tinned. The tin coating lowers the potential difference at the contact point; even so, cover the joint and the cut end with an anti-corrosion coating, and do not install copper above a galvanised part.
Bolt diameter up to one third of the width
BS 7430 and national standard 4123 do not allow a bolt diameter above one third of the busbar width. The largest bolt is therefore M8 for a 25 mm busbar, M10 for 30 mm and M16 for 50 mm.
Plain or tinned?
Plain copper busbar is enough for most applications; use tinned busbar where copper touches galvanised steel or aluminium in air, or where the copper surface must not darken.
Drawing and datasheet
Tinned copper busbar datasheet (PDF)See the dimensions and code table of tinned copper busbar as a PDF, next to the datasheet.
Technical Product Information
Click to view enlarged
Feature | Value |
|---|---|
Product type | Flat tin-coated copper conductor in straight lengths (tinned copper busbar) for bars and bonding, above ground |
Material | Copper with tin coating |
Dimensions (width × thickness) | 25 × 5, 30 × 5 and 50 × 5 mm |
Cross-section | 125, 150 and 250 mm² |
Length | 4 m |
Order code | TBCB 255–505 |
Compatibility | With copper, tinned copper and brass; with galvanised structures only in air, below the galvanised part and with anti-corrosion coating over the joint; avoid connecting to aluminium wherever possible, and if it is unavoidable, make the joint above ground and fully covered |
Tinned copper busbar table: code, dimensions and weight
Order code | Width × thickness (mm) | Cross-section (mm²) | Weight per metre (kg) | Weight per 4 m length (kg) |
|---|---|---|---|---|
TBCB 255 | 25 × 5 | 125 | 1.11 | 4.45 |
TBCB 305 | 30 × 5 | 150 | 1.34 | 5.34 |
TBCB 505 | 50 × 5 | 250 | 2.23 | 8.90 |
We write dimensions as "width × thickness"; in the market the same size is also called "thickness by width", so a 50 × 5 busbar is known as a "5 by 50 busbar". We calculated the weight per metre from the dimensions: cross-section (mm²) × 8.9 ÷ 1000, with a copper density of 8.9 g/cm³; the weight per 4 m length is four times that. We give tinned busbar the same weight as plain copper busbar, because the tin coating is a thin surface layer. All sizes are supplied in 4 m lengths. Our products are continually improved and some dimensions may be updated, so please confirm the final dimensions with our specialists before buying.
Tinned copper busbar dimensions and code table
Download the dimensions and code table (PDF)
How tinned copper busbar is supplied
Tinned copper busbar is the same copper busbar with a layer of tin on its surfaces, supplied in 4 m lengths. It is not a copper-tin alloy: the core is copper, and copper shows at the cut ends and in the drilled holes. For long runs, we supply tinned copper tape in coils.
Click to view enlarged
Applications of tinned copper busbar
- Contact with galvanised structures in air: a copper bar or link connected to a galvanised column, beam or structure, at least 250 mm above ground, with an anti-corrosion coating over the joint and below the galvanised part. To connect tape to a structure, see the tape-to-metal plate bonding clamp.
- Earth bars and bonding bars: earth bars in electrical rooms, substations and transformer rooms, especially in damp conditions; the tinned version of the earth bar without insulators is also made of 50 × 5 busbar. For bonding, see bonding and equipotential bonding.
- Connection with tinned cable lugs: the busbar's tin surface matches a tinned copper cable lug; for bonding panel doors and moving parts, see the flexible bonding tape.
Installation notes
- Cut the busbar to the required length; the cut end and hole show bare copper and must be covered with an anti-corrosion coating where they touch galvanised steel or aluminium.
- Keep the bolt diameter to no more than one third of the busbar width (BS 7430), and do not scrape off the tin coating at the contact point.
- Fasten the connection with a nut, bolt and wide flat washer, with each conductor on its own hole.
- Install tinned busbar above ground; in soil and concrete, use plain copper busbar or copper tape.
Installation tools
Inspection
Tinned copper busbar price enquiry
To ask for a tinned copper busbar price, send our specialists the size, number of lengths and application, and they will give you the current price. The price depends on the day's copper price and the busbar's weight, and tinned busbar costs slightly more than plain busbar because of the tin coating.
Click to view enlarged
On the table of metal potentials, tin is closer than copper to zinc and aluminium. So where the busbar touches galvanised steel or aluminium, tin rather than copper is in contact with them, and the potential difference at the contact point falls. Tin also keeps the busbar's surface from darkening in air and keeps the bolted contact surface clean. The conductivity and weight remain those of copper. The tin coating does not remove the need for an anti-corrosion coating on connections to galvanised steel, because cut ends and holes show bare copper; and in soil, tinned copper behaves just like copper. For long runs, see tinned copper tape.
Advantages of KALOT tinned copper busbar
- Tin surface facing galvanised steel: in air, tin rather than copper touches galvanised steel and aluminium.
- Straight length: for bars and bolted connections that must stay straight.
- Copper weight: the cross-section and weight per metre are the same as plain copper busbar.
- Matches KALOT products: tinned earth bars, tinned cable lugs and copper tapes.
See these products too
Product | When |
|---|---|
For most bars and rigid connections; twenty sizes. | |
Flat tinned conductor in coils for long runs. | |
Ready-made earth bar, on insulators or without them, in copper or tinned. | |
Connects a cable to a bar with a nut and bolt. | |
Bonding of panel doors and moving parts. |
BS 7430:2011 and Iranian national standard 4123 (code of practice for earthing) require copper conductors that touch or rest on galvanised steel to be tinned, require the joint to be at least 250 mm above ground, and do not allow a bolt diameter above one third of the width of a flat conductor.
IEC 62305-3:2010 (protection of structures against lightning) requires a steel-to-copper connection in air, if not welded, to be fully tinned or fully covered with a durable moisture-resistant coating, and notes that a copper part must not be installed above an unprotected galvanised or aluminium part.
Topic 13 of the National Building Regulations sets the minimum cross-section of the main earth bar, with a copper conductor, at 50 mm²; all sizes of our tinned busbar are 125 mm² or more.
Tinned copper bar: section and use
Documents & Downloads
Catalogues & datasheets
Drawings & schematics
Frequently Asked Questions
What is tinned copper busbar and how does it differ from plain copper busbar?
It is the same copper busbar with a layer of tin on its surfaces; it is not a copper-tin alloy. Its cross-section, weight and conductivity are the same as plain copper busbar, and the difference is in the surface: in air, tin rather than copper touches galvanised steel and aluminium.
Where should tinned copper busbar be used?
Where a copper bar or connection touches galvanised steel or aluminium in air, and for earth bars and bonding bars in damp electrical rooms. BS 7430 and national standard 4123 require copper conductors in contact with galvanised steel to be tinned. Avoid connections to aluminium wherever possible, and if one is unavoidable, make it above ground and fully covered.
Can tinned busbar be placed in soil or concrete?
Tinned busbar is for use above ground. In soil and concrete the tin coating brings no advantage, so we recommend plain copper; copper, plain or tinned, is not connected to galvanised parts in soil.
What sizes does tinned copper busbar come in?
In three sizes, 25 × 5, 30 × 5 and 50 × 5 mm, in 4 m lengths. A 50 × 5 busbar weighs 2.23 kg per metre and 8.90 kg per 4 m length. The table on this page gives the weight of every size.
Do cutting and drilling damage the busbar's tin coating?
Cut ends and hole walls show bare copper. Where they touch galvanised steel or aluminium, cover the joint and the cut end with an anti-corrosion coating, and do not scrape the tin off at the contact point.
How does tinned copper busbar differ from tinned copper tape and a tinned earth bar?
Busbar is a flat, straight conductor in 4 m lengths for bars and short connections; tinned copper tape is supplied in coils for long runs, and an earth bar is a ready-made bar installed on insulators or without them.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.