Lightning protection and earthing for refineries, petrochemical plants and oil tanks

In the oil and gas industry, one spark is enough. A spark from lightning, static electricity or a loose connection turns into a fire next to flammable vapour. In reviews of hundreds of tank incidents worldwide, lightning has been the largest single cause of fire. We have worked alongside clients on more than 40 refinery, petrochemical, gas transmission and fuel station projects. This page follows the path of oil and gas from pipeline to control room, and at each stop explains what usually fails and what we do about it.

The product's path, stop by stop

Every stop has a known weak point. We follow the route from the pipeline entry to the control room.

Pipeline entry to the station, at the cathodic protection isolating joint

Pipeline and insulating joint

The problem

A lightning overvoltage on above-ground pipe almost always exceeds what the insulating joint can withstand. The joint sparks over or burns.

Consequence

Leaks and fire at the joint, and a failed cathodic protection system that shows up years later as corrosion.

Our answer:
Bonding and inspection of the insulating joint, plus cathodic protection surge protective devices (SPDs) on the rectifier and monitoring lines.
Substation, switchboards, control system and station telecoms

Booster station and turbocompressor

The problem

Lightning enters switchboards and controllers through power lines, telecom cables and radio antennas.

Consequence

Station shutdown and loss of remote control.

Our answer:
Overvoltage protection design with power and data surge protective devices at the boundary of each zone, an integrated earthing network and KALweld® exothermic welding for buried joints.
Columns, exchangers, pumps and piping in Zone 0, 1 and 2

Process units and hazardous areas

The problem

If lightning current passes through a loose bolted joint, or through a conductor without enough separation distance, it sparks right there.

Consequence

Ignition of an explosive mixture.

Our answer:
Lightning risk assessment, isolated air terminals that respect the separation distance, a ring earth electrode and bonding of every metal part with connections that will not loosen under vibration.
Fixed roof and floating roof tanks

Tanks and tank farms

The problem

In a floating roof tank, lightning current passes where the roof meets the shell. Old shunts make poor contact because of rust and wax deposits, and they arc right there.

Consequence

A rim seal fire which, if the roof sinks, becomes a full surface tank fire. Earthing the tank alone does not prevent this.

Our answer:
The ARG® bonding device for floating roof tanks, designed and manufactured by KALOT Group, which keeps the bonding path between roof and shell intact as the roof rises and falls, together with bonding conductors and periodic inspection.
Loading of tankers, drums and IBCs; petrol and CNG stations

Loading bays and fuel stations

The problem

When liquids are transferred, static charge builds up on the tanker, hose and nozzle. If a single metal part is not bonded, it sparks.

Consequence

Major fires that safety investigators have traced to static sparks caused by incomplete bonding.

Our answer:
Bonding clamps, earth bars and bonding continuity testing.
DCS, telemetry, fire detection and suppression

Control room, fire alarm and SCADA

The problem

The system that should detect a fire during a storm is itself knocked out by the surge.

Consequence

The fire is seen too late and the suppression command never arrives.

Our answer:
Data line surge protective devices (SPDs) and fire alarm surge protective devices (SPDs) on every circuit running from the site to the control room.

Hazardous zones and the action they need

At a glance: which layer of protection matters most in each zone.

ZoneStructural lightning protectionBonding and earthingSurge protective devices (SPDs)Static electricity
Zone 0 and 1 (inside and near the vapour source)Essential, with separation distanceSpark-free connectionExplosion-proof typeEssential
Zone 2 (low likelihood of vapour)Based on risk assessmentEssentialEssentialAt loading points
Floating roof tankTank shell as a natural conductorRoof-to-shell bondingOn fire detectorsEssential
Control room and substationEssentialIntegrated earthing networkPower and data

Reference: IEC 62305-2 and 3 (Annex D), API RP 545, API RP 2003, IEC/TS 60079-32-1, IEC 61643

How we see our work in this industry

Most of our projects in this industry have started with one thing in common: the existing earthing system was complete on paper, but the bonds had rusted or loosened over the years. That is why on every project we measure and test first, then design. We weld the underground connections so they do not fail in the corrosive soil of oil sites, and for floating roof tanks we recommend ARG®.

Some of our projects

Refineries: Tabriz Refinery, Lavan Refinery, the blending tower of Behran Oil Refinery, the Research Institute of Petroleum Industry

Petrochemicals: Bandar Imam Khomeini, Amirkabir, Takht-e Jamshid and Laleh petrochemical companies in Mahshahr; Ibn Sina Petrochemicals and Assaluyeh Petrochemical; Kermanshah, Arak, Alvand, Pars and Dehdasht petrochemical companies; Arya Sasol Polymer; Bandar Abbas petrochemical storage facilities

Oil and gas transmission and storage: Imam Khomeini oil tanks in Bushehr, Omidiyeh gas tanks, Farashband gas booster station, Zanjan gas transmission line, Gas Transmission Operations Region Five, Arak and Kermanshah oil pipelines and telecoms, South Zagros Oil and Gas Production, the NGL 3100 project in Dehloran, gas maintenance yards

Fuel stations: CNG stations in Lordegan and Amol and petrol stations in Rasht

What to send for design and a quotation

Hazardous area classification drawing, tank layout with roof type and diameter, pipeline routes and the location of insulating joints, a list of panels and control systems, and the report of the latest earth test.

Frequently Asked Questions

Is earthing a tank enough to protect it against lightning?

No. Recorded incidents show that an earthed tank can still catch fire from lightning. In a floating roof tank, the current path between the roof and the shell is decisive and must be controlled with suitable bonding.

Why does a pipeline insulating joint need a spark gap?

Lightning overvoltage exceeds what the insulation can withstand and breaks down the joint. An explosion-proof spark gap connects both sides in a controlled way at the moment of the strike, and in normal operation keeps the isolation needed for cathodic protection.

How often should loading rack bonding be tested?

Bonding continuity and earth resistance at loading points are tested regularly, because clamps and cables get damaged in daily work and corrosion raises the contact resistance.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.