KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original
Lightning protection clamps, connectors and fittings

Complete Product Overview

Square four-way tape-to-tape clamp

Last updated:

The KALOT square four-way clamp connects flat tape to flat tape, in copper or stainless steel, in the conductor network of lightning protection and earthing systems. The two tapes sit in the grooves of the upper part (cover) and lower part (base), and tightening four stainless steel bolts at the four corners joins both conductors evenly, mechanically and electrically; a separate countersunk hole in the centre of the base fixes the clamp to the structure. The four-way geometry lets the same clamp make cross joints, T branches and straight tape joints. It is produced in three models, STCC 253, STCC 303 and STCC 505, for tapes of different sizes: 25×3, 30×3 and 50×5 mm.

We supply this clamp for clean, firm and inspectable joints in the copper or stainless steel tape network of your project.

What does the square four-way tape-to-tape clamp do?

In the tape network of a lightning protection and earthing system, wherever two tapes, whether copper or stainless steel, meet or the route branches, you need a part that makes a firm, inspectable joint, both mechanically and electrically, without welding. In the KALOT square clamp, the two tapes sit between the upper part (cover), with its central circle and the raised KALOT ABHAR brand lettering, and the lower part (base), and four stainless steel bolts at the four corners clamp the two parts onto the tapes. A separate countersunk hole in the centre of the base fixes the clamp to the structure or wall independently of these four bolts.

Three joint layouts with one clamp

  • Cross joint: two tapes at right angles pass through the clamp and connect where they cross; both tape runs continue.
  • T branch: one tape passes through the clamp while the other ends at the same point and branches off.
  • Straight joint: the two ends of a tape meet in one line, with the clamp as their connecting point.

Use in air terminal and down conductor networks

This clamp is used mostly in connections for air terminals (the roof tape network) and down conductors of lightning protection systems, especially in designs carried out to IEC 62305. The number and exact position of the clamps on each project are set by the system designer, based on the conductor routes and the requirements of the standard.

Why four bolts?

The four bolts sit at the four corners of the body, with the tape crossing point in the centre between them, so tightening the bolts evenly in a cross pattern applies the clamping force symmetrically over the contact area of the two tapes. In the KALOT ABHAR manufacturing drawing, the channel depth of each part is less than the tape thickness, so in a cross joint the two tapes are pressed directly onto each other at the crossing point as the bolts are tightened.

Material and compatibility

The clamp body is made of quality brass and its bolts of stainless steel. Brass belongs to the same family as copper tape and is also compatible with stainless steel tape. Please note that this clamp is not suitable for steel, galvanised or aluminium tapes, because corrosion would occur between them. KALOT manufactures its own dedicated products for those connections as well.

Installation and inspection notes

If the clamp must be fixed to the structure, first fix the lower piece to the surface through its central recessed hole with a countersunk screw, so the screw head sits under the tapes; once the tapes are in place, this hole can no longer be reached. Clean paint, grease or heavy oxide from the tapes and the clamp, lay the tapes on the base, place the upper piece, then hand-start the four corner bolts and tighten them gradually in a crosswise order. At periodic inspections, check that the bolts are tight and that there is no corrosion or unusual discolouration, and measure the electrical continuity of the route if needed.

Choosing the right model

Choose the clamp model by the size of the tape you use: STCC 253 for 25×3 tape, STCC 303 for 30×3 tape and STCC 505 for 50×5 mm tape (the larger tape family). The clamp height rises from 13 to 22 mm, so allow installation space accordingly. For other tape sizes, please check with KALOT Group before ordering; for a simpler joint of two tapes in line, the KALOT two-way tape-to-tape clamp is another option.

Technical Product Information

Feature

Value

Product type

Square four-way tape-to-tape clamp (Square Tape Clamp)

Body material

Brass

Bolt material

Stainless steel

Number of cover bolts

4 (one at each corner)

Base fixing hole

1 recessed hole in the centre of the lower piece, separate from the four cover bolts

Structure

Two pieces: upper piece with a central circle and raised KALOT ABHAR lettering, lower piece with the base fixing hole

Conductor type

Flat copper and stainless steel tape (two tapes per clamp)

Connection type

Mechanical, bolted; cross, T and straight layouts

Main application

Air terminal, down conductor and earthing tape networks

Available models

⁦STCC 253⁩, ⁦STCC 303⁩, ⁦STCC 505⁩

Related standards

IEC 62561-1 (connection components) and IEC 62305-3 (system design and installation), for reference.

How to choose a model

By copper tape size (25×3, 30×3 or 50×5 mm)

Dimensions and order code

Product code

Tape size (mm)

L (mm)

W (mm)

H (mm)

⁦STCC 253⁩

⁦25×3⁩

60

60

13

⁦STCC 303⁩

⁦30×3⁩

70

70

14

⁦STCC 505⁩

⁦50×5⁩

79

79

22

L is the length, W the width and H the height of the clamp; each dimension is marked on the drawing in the "Technical drawing and dimensions" tab. For other tape sizes, please speak to us before ordering.

Cross clamps for wire and tape

Drag to rotate; scroll to zoom.Open full screen

Frequently Asked Questions

What is a square four-way tape-to-tape clamp used for?

It joins flat copper tape to flat copper tape in the air terminal, down conductor and earthing network of a lightning protection system. The two tapes sit between the two body pieces and are held by four corner bolts.

What is the difference between cross, T and straight joints?

In a cross joint, two tapes at right angles pass through the clamp and both runs continue. In a T branch, one tape passes through and the other branches off at the same point. In a straight joint, the two ends of a tape meet in one line. All three layouts work with this same clamp, with no extra parts.

How do we choose the right clamp model?

It depends on the copper tape size: STCC 253 for 25×3 tape, STCC 303 for 30×3 and STCC 505 for 50×5 mm tape. For other sizes, please speak to KALOT Group before ordering.

What is the clamp body made of?

The body is brass and the bolts are stainless steel. Pairing brass with ordinary or galvanised steel bolts can worsen galvanic corrosion, especially where moisture and an electrolyte are present. Stainless steel bolts are used to raise corrosion resistance and keep the joint sound over time. For galvanised steel or aluminium tape networks, or for installation in corrosive environments or underground, check material compatibility with the KALOT Group technical team before installation.

What is the hole in the middle of the lower piece for?

This recessed hole fixes the clamp to the structure's surface and is separate from the four bolts that close the two pieces over the tapes. Because it ends up under the tapes after installation, fix the base with a countersunk screw before laying the tapes. Opening and closing the cover bolts during inspection does not disturb how the clamp is held on the structure.

What should we keep in mind during installation?

Clean the tape surfaces and the clamp channels, lay the tapes in the layout your project needs, then tighten the four corner bolts gradually in a crosswise order so the pressure stays even. To fix the clamp to the structure, use the centre hole in the lower piece.

How is this connection checked during periodic inspections?

Check that the bolts are tight, the body is sound and there is no corrosion or unusual discolouration, and measure the electrical continuity of the route if needed. If the connection has loosened, retighten the bolts evenly.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.