Move your pointer over the image to zoom in
Complete Product Overview
One-piece tape-to-pipe bonding clamp
Order Code: WMPB 026
Last updated:
The KALOT one-piece tape-to-pipe bonding clamp (model WMPB 026) bonds flat copper tape to large-diameter metal pipes, connecting the pipe to the earthing and lightning protection system.
The cast brass body with its concave base sits on the pipe, the tape goes around the pipe, and one stainless steel bolt tightens both ends of the tape to the clamp, with no drilling or welding on the pipe.
For tape up to 26 mm wide; body dimensions 40 × 30 mm.
We provide this clamp for reliable bonding of your project's metal pipework to its earthing and lightning protection systems. Tell us the pipe diameter and we will recommend the most suitable clamp.
Bonding metal pipes with copper tape, without drilling the pipe
Metal pipes in a facility, such as the water main, usually need bonding to the earthing network and lightning protection system so that no dangerous potential difference arises between them and other metal parts. This clamp connects copper tape to the pipe without drilling or welding; which pipes and bonding points to use is for the system designer to decide.
Tape-to-metal pipe connection
The copper tape sits around the pipe and is tightened to it by the clamp, with no drilling or welding on the pipe.
For bonding and earthing
Designed to bond copper tape to large-diameter metal pipes in earthing and lightning protection systems.
Concave base to suit the pipe
The base of the body is curved and sits on the pipe surface; the curvature of the clamp must suit the curvature of the pipe.
Inspectable mechanical connection
The connection is bolted with no welding; during periodic inspection you can check the tightness of the bolt and the condition of the tape contact.
Stainless steel bolt
To increase corrosion resistance and the long-term durability of the connection in the brass body.
Technical Product Information
Feature | Value |
|---|---|
Product type | One-piece tape-to-pipe bonding clamp (Watermain Pipe Bond) |
Body material | Brass (cast) |
Bolt | One, stainless steel |
Structure | One-piece body with concave base, tape channel and one central bolt |
Conductor | Flat copper tape up to 26 mm wide |
Body dimensions | Length L = 40 mm, width W = 30 mm |
Installation location | Large-diameter metal pipe; the curvature of the clamp base must suit the curvature of the pipe |
Preparation | The two ends of the tape are drilled at the bolt position; the pipe is not drilled |
Order code | WMPB 026 |
Order code | Maximum tape width (mm) | Length L (mm) | Width W (mm) | Material |
|---|---|---|---|---|
WMPB 026 | 26 | 40 | 30 | Brass, stainless steel bolt |
The positions of L and W are shown in the "Technical drawing and dimensions" tab. The curvature of the clamp base suits large-diameter metal pipes; tell us the outside diameter of your project's pipe and we will recommend the most suitable clamp.
Click to view enlarged
The KALOT three-view drawing shows the front, top and side views of the clamp: the tape channel on the body, the central bolt and the concave base that sits on the pipe. Dimensions: L = 40 mm · W = 30 mm, maximum tape width 26 mm. This is not a manufacturing drawing; its PDF and SVG files are in the "Catalogues and documents" section of this page.
Click to view enlarged
Application
This clamp bonds large-diameter metal pipes, such as the water main and other metal pipework in a facility, to the earthing network and lightning protection system using copper tape. After connecting to the pipe, the tape continues as the bonding conductor to the bonding bar, the earthing network or the protection system conductor. Which pipes are bonded, and at which points, is decided in the system design and according to local regulations.
Choosing between KALOT bonding clamps
- Large-diameter metal pipe that suits the clamp's curvature: this clamp, WMPB 026.
- Pipes and round objects of different diameters, such as rainwater pipes and railings: two-piece tape-to-pipe bonding clamp (RWPB 026).
- Flat steel structure: tape-to-metal plate bonding clamp (BBCS 253).
Installation sequence
- Check the outside diameter of the pipe; the base of the clamp must sit fully on it. The tape must also be no wider than 26 mm.
- Check that the pipe material is compatible with copper and brass (see the "Technical notes" section).
- Clean dirt, rust and loose coating from the contact area on the pipe so that the tape and clamp make reliable contact with the pipe metal. Any removal of the pipe's protective coating must follow the design, and the necessary protection must be applied after installation.
- Place the clamp on the pipe and take the tape around the pipe, then drill both ends of the tape at the position of the clamp bolt. Choose a hole size to suit the bolt supplied.
- Pass the bolt through the holes in both ends of the tape and tighten gradually and evenly until the clamp sits flat and fully on the pipe and the tape is firm around it.
- Connect the rest of the tape to the bonding bar, the earthing network or the protection system conductor.
- After installation, check the tightness of the connection and the electrical continuity of the path.
Technical notes and limitations
- The curvature of the clamp base is fixed and this clamp suits a specific pipe size; for bonding pipes of different diameters, we recommend the two-piece tape-to-pipe bonding clamp.
- In KALOT brass clamps, a stainless steel bolt helps reduce the risk of corrosion at the connection and keeps the joint mechanically stable over time, especially in damp or corrosive environments.
- Pipe material: direct contact between copper or brass and a galvanised steel or aluminium pipe, especially in the presence of moisture, can aggravate galvanic corrosion. Material compatibility and, where needed, the method of protection should be decided by the system designer.
- Non-metallic pipes (such as PVC and polyethylene) are not conductive and are not bonded with this clamp.
Inspection and maintenance
During periodic inspections of the earthing and lightning protection systems, check this connection for a loose bolt, tape movement or slipping, corrosion and mechanical damage, and measure the electrical continuity of the path if needed. After each opening and closing, tighten the bolt evenly again.
The following standards are the reference for the design, installation and selection of connection components in lightning protection systems.
System design standard: IEC 62305-3
This standard covers the design, installation, inspection and maintenance of lightning protection systems for structures. Equipotential bonding of metal services entering the structure, such as metal pipes, to the protection system is one of the ways to prevent dangerous sparking; connections must be reliable and checked during periodic inspections. Choosing the pipes and bonding points is the responsibility of the system designer.
Bonding clamps for tape to pipe and metal plate
Frequently Asked Questions
What is a tape-to-pipe bonding clamp used for?
This clamp bonds copper tape to large-diameter metal pipes in earthing and lightning protection systems, with no drilling or welding on the pipe.
What pipe diameter is this clamp suitable for?
For large-diameter metal pipes. The base of the clamp has a fixed curvature that must suit the curve of the pipe, so tell us the outside diameter of your project's pipe before ordering and we will recommend the most suitable clamp.
What size of tape is used with this clamp?
Flat copper tape up to 26 mm wide.
Can it be used on a water pipe?
The technical name of this clamp (Watermain Pipe Bond) refers to bonding metal water mains, and it can be used on a metal water pipe of suitable diameter. Plastic pipes are not conductive and are not bonded. Whether a given pipe needs bonding is decided by the system design and local regulations.
Which clamp should I use for a rainwater pipe or pipes of different diameters?
For rainwater pipes, railings and pipes of different diameters, the KALOT two-piece tape-to-pipe bonding clamp (RWPB 026) is the better choice, because the tape wraps around the round object and does not depend on a fixed clamp curvature. The one-piece clamp is for large-diameter metal pipes that suit the curvature of its base.
Is it used for earthing, bonding and lightning protection systems?
Yes. This clamp is designed to connect metal pipes to earthing and lightning protection systems using copper tape. The locations and number of bonding points are decided by the system designer.
Does the pipe surface need preparing before installation?
Yes. As a general technical principle, the contact area must be clean and free of rust, dirt and loose coating so that a reliable electrical connection is made. Any removal of the pipe's protective coating must follow the design, and the necessary protection must be applied after installation.
Can this connection be inspected?
Yes. The connection is bolted and mechanical, so during periodic inspection you can check the tightness of the bolt, the condition of the tape, corrosion and electrical continuity.
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.