KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original

Earthing, bonding and lightning protection for railways and metros

On a railway, the rail itself is an electrical conductor. In a metro, traction current returns through the rails and part of it leaks into the soil and the tunnel reinforcement. On intercity lines, lightning strikes the rails or trackside equipment, and the signalling system, which for safety is designed to turn everything red on a fault, stops the whole section. We have worked alongside clients at metro stations in Tehran, Isfahan and Mashhad, on the Qom Monorail and on railway station telecoms along the northern line and in Semnan and Lorestan.

Metro and light railDC traction: stray current, corrosion of reinforcing bars and pipes, rail voltage at platforms
Intercity railwaysLightning on the line, signalling systems and telecom masts on mountain routes

Along the line, stop by stop

A red "DC" label means metro and light rail only; the other stops apply to both types of line.

Traction substationDC

The problem

The traction substation is both where current is fed into the rail and where rail-to-earth voltage reaches its highest value.

Our answer:
Substation earthing grid, earth bars and equipment bonding to the traction consultant's design.

Rails and the current return pathDC

The problem

If the rail insulation to earth is weak, traction current leaks into the soil. This stray current corrodes the reinforcing bars of structures and nearby gas and water pipes where it leaves the metal. On urban rail networks worldwide, repairing stray current damage has cost operators dearly.

Our answer:
Accessible test points and coordination with the pipe owners and their cathodic protection.

Overhead line masts and third rail

The problem

If an insulator breaks or a wire snaps, the mast, the railings and any metal near the line become live. These parts must be connected to the common earthing system so that protection trips at once.

Our answer:
Bonding design, KALweld® exothermic welding, bonding clamps and continuity testing.

Station platformDC

The problem

If rail voltage exceeds the permissible touch voltage, a passenger touching the train and the platform railing at the same time is at risk.

Our answer:
Measurement, station earthing design and bonding of the platform's metalwork.

TunnelDC

The problem

If the tunnel's reinforcing bars are not continuously bonded, they collect and discharge stray current at scattered points, and corrosion happens where no one can see it.

Our answer:
Continuous bonding of the reinforcing bars and accessible test points, before the concrete is poured.

Signalling cabinets, interlocking and level crossings

The problem

A strike on the rail carries high voltage into the electronic signalling equipment. The system shuts down to its safe state and every signal in the area turns red. In one case, the line stayed closed until further notice. Long trackside cables to level crossings and points also pick up induced voltage.

Our answer:
Cabinet earthing, cable screen bonding and data line surge protective devices (SPDs) at the cable entry.

Telecoms and radio masts

The problem

Railway telecom masts often stand on high, exposed points along mountain routes, where the chance of a direct strike is high.

Our answer:
Air terminals on the mast, a ring earth, bonding to the equipment room busbar and power, RF and data SPDs. This is the work we carried out for the station telecoms at Savadkuh, Pol-e Sefid, Zirab and Firuzkuh.

Depot and workshop

The problem

In the workshop, people work beside the rails and under the trains, so the touch voltage limit is stricter.

Our answer:
Depot earthing grid, temporary earthing points and periodic testing.

References: EN 50122-1 and 2, EN 50162, IEC 62497, EN 50124, IEC 62305-4

Some of our projects

Metro and urban rail: Garmdarreh, Atmosfer, Ekbatan, Azadi Stadium and Mohammadshahr stations; Metro Line 10 to Imam Khomeini Airport; Mashhad urban rail Line 2; Isfahan Metro; Qom Monorail; the head office of Tehran Urban and Suburban Railway

Railway station telecoms: Tehran, Firuzkuh, Sorkhabad, Savadkuh, Zirab, Pol-e Sefid, Shirgah, Zarrindasht, Sari, Behshahr, Rahbisheh

Semnan and Damghan railway: Larestan, Gerdab and Haftkhan stations

Buildings: the head office of RAJA Passenger Trains

What to send for design and a quotation

Traction system type (DC or AC), route and station drawings, the location of traction substations, the layout of signalling cabinets and telecoms masts, and for tunnels, the reinforcement drawing before concrete is poured.

Frequently Asked Questions

What damage does metro stray current cause?

Current leaking from the rails into the soil corrodes metal at the point where it leaves it. Tunnel reinforcement and gas and water pipes near the line suffer the most damage.

Why does lightning bring a whole railway section to a halt?

Because the signalling system goes to a safe state on any fault and turns every signal red. Surge protective devices and proper earthing of the cabinets prevent these stoppages.

When should tunnel reinforcement bonding be done?

Before the concrete is poured. After that, the reinforcement is practically out of reach.

Have a Technical Question?