Move your pointer over the image to zoom in
Complete Product Overview
Franklin France lightning strike counter (air terminal counter)
Last updated:
The Franklin France air terminal counter, or lightning strike counter, is installed on the down conductor and records the number of lightning discharges that pass through it. It tells the operator that strikes have occurred and helps plan technical visits and checks of the lightning protection system on a better-informed basis. To ask for a price and buy a lightning counter that suits your project equipment, contact the KALOT specialists. This counter is made to IEC 62561 and has a test certificate.
Franklin France lightning counter: recording strikes without power or batteries
The Franklin France AFV1007CF lightning counter is an electromechanical counter that records the number of lightning strikes whose current passes through the down conductor of the protection system. It mounts on the conductor and shows the number of logged events on its display, a simple way for the operator to read the counter at each inspection and follow how it changes.
Independent operation, no power supply to worry about
One practical feature of this lightning counter is that it works with no external power and no battery. Both the counting section and the display work independently, so it needs neither a supply cable nor battery changes. The manufacturer also specifies no particular maintenance for the counter itself.
Fits on the conductor without cutting its path
The AFV1007CF counter mounts directly on a flat or round conductor with special clamps, with no need to cut the conductor or break its continuity. The clamps required come with the device and suit flat conductors up to 30 × 3.5 mm and round conductors up to 10 mm in diameter. This makes it possible to fit the counter to the down conductor without interrupting its path.
Six-digit display to track the number of strikes
The device's six-digit display shows numbers from 0 to 999999. The benefit for the operator is clear: they can record the reading at each inspection and compare it with the previous one to see how many events were logged between the two visits.
Clear specifications to match your project
This model has a polycarbonate housing and 304L stainless steel clamps. Its declared specifications include IP65 protection, an operating temperature of -10 to +60 °C and a weight of 500 g. The standard stated in the brochure is NF EN IEC 62561-6, second edition. When choosing a counter, review these specifications along with the conductor type and the conditions at the installation site.
Technical Product Information
Property | Value / notes |
|---|---|
Product code |
|
Classification |
|
Minimum impulse discharge current (Iimp min) | 2 kA with |
Maximum impulse discharge current (Iimp max) | 100 kA with |
Display | 6 digits, from 0 to 999999 |
Housing and clamp material | Polycarbonate housing; 304L stainless steel clamp |
Mounting on the conductor | Flat conductor up to 30 × 3.5 mm or round conductor up to 10 mm in diameter; the special clamps come with the device. |
Operating temperature | From -10 to +60 °C |
Relative humidity | From 0 to 100 percent |
Maximum operating altitude | 4000 m above sea level |
Degree of protection | IP65 |
Weight | 0.500 kg, equal to 500 g |
Maintenance | Not required, according to the manufacturer's brochure. |
Warranty stated in the brochure | 1 year |
Standard stated in the brochure | NF EN IEC 62561-6 Ed2: second edition |
Click to view enlarged
Click to view enlarged
Installing an ESE air terminal on a telescopic mast
Documents & Downloads
Catalogues & datasheets
- Download datasheetLanguage: English · Version: FT117EN.QLF.01 (opens in a new tab)
- Franklin France general catalogue of lightning and overvoltage protection products 2026Version: CP001FR.QLF.07 (opens in a new tab)
- Franklin France AFV1007CF electromechanical lightning strike counter datasheetVersion: FT117FR.QLF.01 (opens in a new tab)
Similar & Complementary Products
Have a Technical Question?
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.