Telecom, data and dispatch centreService
At one emergency centre, five operators received electric shocks through their telecom equipment while on calls at the moment of a lightning strike.
A government building is more than an office building. If it stops working, a service to the public is interrupted. If it burns, a document that cannot be replaced may be lost. That is why a lightning risk assessment weighs "loss of public service" and "cultural heritage" separately, in addition to human life. We have worked alongside clients in more than 80 government and public buildings, from ministries and provincial governorates to seismograph stations, water and power companies and museums.
A filled dot means this loss is usually decisive for this type of building.
| Building type | Life | Public service | Heritage | Economic |
|---|---|---|---|---|
| Ministries and provincial governor offices | ||||
| Telecom, data and dispatch centre | ||||
| Archives, libraries and museums | ||||
| Courts and forensic medicine | ||||
| Historic building | ||||
| Remote sites (seismic, weather stations) |
Reference: IEC 62305-2
A chain of events repeated in reports from several emergency centres around the world:
In one of these reports, an emergency centre was damaged despite having an "extensive earthing system". The lesson: an earth electrode alone is not protection. Bonding, surge protective devices on power, radio, telephone and data lines, and dividing the building into protection zones are needed too.
At one emergency centre, five operators received electric shocks through their telecom equipment while on calls at the moment of a lightning strike.
In 2024, lightning set fire to the roof of a country's national archives building, and most of the records in one block were lost.
Old buildings were never designed for lightning. A single down conductor is no longer considered enough, and side flashes travel through mortar joints and split the wall.
Antennas added to office building roofs years later are usually left unbonded, and their cables enter the building wherever they can.
On multi-building sites, fire alarm loops run in the open carry surges to the fire alarm panel.
Seismic and weather stations sit on high elevations with rocky soil, and nobody is on hand there all the time.
Reference: IEC 62305-2 to 4, IEC 61643-11 and 21, IEC 60364-5-54, ITU-T K.27 and K.112, IEC 60728-11
National institutions: the Islamic Consultative Assembly (Parliament), the Supreme Audit Court, the Tehran Stock Exchange, the Iran Chamber of Commerce, the head office buildings of the Ministry of Labour, the Ministry of Science and the Ministry of Housing, the Red Crescent and the Relief Committee
Provincial and municipal: the governorates of Bushehr, Qom and Qazvin, the Justice Department of Chaharmahal and Bakhtiari, the forensic medicine centres in Rasht and Kerman, and Tehran Municipality District 9
Infrastructure: seven seismograph stations and centres, the General Meteorological Office, the National Cartographic Centre, Tehran Province Water and Wastewater, the Tehran wastewater treatment plant, the Bandar Imam Khomeini telecommunications centre and the Alborz Space Centre
Cultural: the Central Bank Treasury Museum, the Holy Defence Museum and the Organisation for the Reconstruction of the Holy Shrines
Type of use and number of occupants, services that must not be interrupted, a list of telecoms and data systems, rooftop antennas, year of construction and any restrictions on the building's appearance.
No. Lightning protection keeps the structure safe from fire and damage. Electronic equipment is protected by SPDs and bonding.
Because the assessment also counts the loss of "public service" and sometimes of "cultural heritage", which raises the protection level required.
Conductor routes should be discreet, joints between dissimilar metals need an anti-corrosion coating, and earth electrode positions must be coordinated with the services and historic layers below ground.
KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.