KALOT Group
This translation is an AI-assisted draft pending human review. It is not indexed for search yet.Read the reviewed Persian original

Lightning protection and earthing for office and government buildings

A government building is more than an office building. If it stops working, a service to the public is interrupted. If it burns, a document that cannot be replaced may be lost. That is why a lightning risk assessment weighs "loss of public service" and "cultural heritage" separately, in addition to human life. We have worked alongside clients in more than 80 government and public buildings, from ministries and provincial governorates to seismograph stations, water and power companies and museums.

Four types of loss

LifeStaff and visitors
Public serviceInterruption of a service people depend on
Cultural heritageIrreplaceable documents, books and buildings
EconomicEquipment, data and repairs

A filled dot means this loss is usually decisive for this type of building.

Building typeLifePublic serviceHeritageEconomic
Ministries and provincial governor offices
Telecom, data and dispatch centre
Archives, libraries and museums
Courts and forensic medicine
Historic building
Remote sites (seismic, weather stations)

Reference: IEC 62305-2

Public service: one lightning strike, weeks of outage

A chain of events repeated in reports from several emergency centres around the world:

  1. 1. Lightning strikes the building or an incoming line
  2. 2. Telephones, radios and systems fail
  3. 3. Calls are diverted to another centre
  4. 4. The next day, the main centre is still down
  5. 5. Weeks of repairs and equipment replacement

In one of these reports, an emergency centre was damaged despite having an "extensive earthing system". The lesson: an earth electrode alone is not protection. Bonding, surge protective devices on power, radio, telephone and data lines, and dividing the building into protection zones are needed too.

What each type of building needs

Telecom, data and dispatch centreService

The problem

At one emergency centre, five operators received electric shocks through their telecom equipment while on calls at the moment of a lightning strike.

Our answer:
Bonding of consoles, telephones and power in the room, and power surge protective devices (SPDs) and data line SPDs at the entry point.

Archives and librariesHeritage

The problem

In 2024, lightning set fire to the roof of a country's national archives building, and most of the records in one block were lost.

Our answer:
External lightning protection to prevent fire, and bonding of roof metalwork.

Historic buildingHeritage

The problem

Old buildings were never designed for lightning. A single down conductor is no longer considered enough, and side flashes travel through mortar joints and split the wall.

Our answer:
Specialist design with low-visibility routes, taking account of services and historic layers beneath the site, and testing after every lightning strike.

Rooftop antennasEconomic

The problem

Antennas added to office building roofs years later are usually left unbonded, and their cables enter the building wherever they can.

Our answer:
Placing antennas inside the protected zone, bonding the mast, and a coaxial surge protective device at the cable entry.

Fire alarm between buildingsLife

The problem

On multi-building sites, fire alarm loops run in the open carry surges to the fire alarm panel.

Our answer:
Fire alarm surge protective devices (SPDs) on the loops between buildings and on the panel supply.

Remote sitesService

The problem

Seismic and weather stations sit on high elevations with rocky soil, and nobody is on hand there all the time.

Our answer:
An integrated site earthing system with GIM ground improvement material, surge protective devices and periodic inspection. We have done this at seismic stations in Golestan, Bushehr, Tabas, Shahrokht, Damavand, Zahedan and Asaluyeh.

Reference: IEC 62305-2 to 4, IEC 61643-11 and 21, IEC 60364-5-54, ITU-T K.27 and K.112, IEC 60728-11

Some of our projects

National institutions: the Islamic Consultative Assembly (Parliament), the Supreme Audit Court, the Tehran Stock Exchange, the Iran Chamber of Commerce, the head office buildings of the Ministry of Labour, the Ministry of Science and the Ministry of Housing, the Red Crescent and the Relief Committee

Provincial and municipal: the governorates of Bushehr, Qom and Qazvin, the Justice Department of Chaharmahal and Bakhtiari, the forensic medicine centres in Rasht and Kerman, and Tehran Municipality District 9

Infrastructure: seven seismograph stations and centres, the General Meteorological Office, the National Cartographic Centre, Tehran Province Water and Wastewater, the Tehran wastewater treatment plant, the Bandar Imam Khomeini telecommunications centre and the Alborz Space Centre

Cultural: the Central Bank Treasury Museum, the Holy Defence Museum and the Organisation for the Reconstruction of the Holy Shrines

What to send for design and a quotation

Type of use and number of occupants, services that must not be interrupted, a list of telecoms and data systems, rooftop antennas, year of construction and any restrictions on the building's appearance.

Frequently Asked Questions

If a building has lightning protection, does that also protect its equipment?

No. Lightning protection keeps the structure safe from fire and damage. Electronic equipment is protected by SPDs and bonding.

Why is the risk assessment for a government building different from that for an ordinary office building?

Because the assessment also counts the loss of "public service" and sometimes of "cultural heritage", which raises the protection level required.

What should be considered for lightning protection on a historic building?

Conductor routes should be discreet, joints between dissimilar metals need an anti-corrosion coating, and earth electrode positions must be coordinated with the services and historic layers below ground.

Have a Technical Question?

KALOT Group's technical experts are ready to answer your questions about lightning rods and earthing systems.