Comparison of Franklin France ESE air terminal models

This table compares the three Franklin France ESE air terminal families, ACTIVE 1D+, ACTIVE 2D and ACTIVE 4D, by model, early streamer emission time ΔT, operating method, testing and monitoring features, and installation details. It helps designers and clients see the differences between models at a glance and, when buying an ESE air terminal, pick the right option for the project to examine more closely.

Compare the performance, models, and testing and monitoring features of the three ACTIVE families at a glance.

Comparing Electronic Lightning Rod Models

For a faster decision, compare each model's key features in one readable table.

FeatureActive 1D+ ESE air terminal made by Franklin France on a blue backgroundACTIVE 1D+ ESE air terminalThe newest, simplest and most varied Franklin France ESE air terminal in terms of early streamer emission time ΔTActive 2D Franklin France electronic lightning rodACTIVE 2D ESE air terminalA more advanced model than ACTIVE 1D+ that uses two devices, Impulse and Power, to create and propagate the upward leader (Upward Leader)Active 4D Franklin France electronic lightning rodACTIVE 4D ESE air terminalMore advanced than ACTIVE 2D, predicting an approaching storm from 30 km away, logging data in LMS software and with a lightning counter built into the device
Country of ManufactureFranklin FranceFranklin FranceFranklin France
Air terminal typeNew-generation ESE air terminalESE air terminal with dual systemConnected lightning protection and monitoring system
Operating technologyInternal mechanism triggered by the electric field of the stormTwo methods of creating and propagating the upward leader, using two devices, Impulse and PowerDual 2D technology with storm monitoring and communication system
Early streamer emission time ΔT12, 25, 45 or 60 microseconds30 or 60 microseconds30 or 60 microseconds
Main standardNF C 17-102:2011NF C 17-102:2011NF C 17-102:2011
Protection radius RpDepends on ΔT, installation height and protection level I to IVDepends on ΔT, installation height and protection level I to IVDepends on ΔT, installation height and protection level I to IV
Energy sourceNo external power: uses the natural corona effectFrom the electrostatic field of the storm, solar cells and power capacitors (no external power)Impulse and Power DevicesFrom the electrostatic field of the storm, solar cells and power capacitors (no external power)Impulse and Power Devices
On-site function testYesOnly with the wired tester on a telescopic mastYesWith the remote tester, wireless, from 100 m awayYesWith the Activ’Control unit, wireless, from 100 m away
Standard test methodAFV0050TT wired tester; AFV0087PT test pole can be usedRemote radio tester; also wired tester and test poleRadio test, or test through Activ’Control and LMS software
Test from ground levelWith a telescopic pole, up to a height of about 8 mYes, without opening the device and from 100 m awayYes, remotely through the control system, from 100 m away
Lightning counterYes, supplied separatelyYes, supplied separatelyLightning counter built into the device
Logging of lightning strike detailsAdvanced detail logging not includedAdvanced detail logging not includedLogs the number, date, time, magnitude, waveform and energy of the lightning currents captured, stored in LMS software
Approaching storm detectorStandalone storm warning not includedStandalone storm warning not includedIntegrated advanced storm detection and warning system
Real-time monitoring and displayNoNoYes: lightning data and system and device status shown online
Controller and softwareNot requiredStandalone radio testerActiv’Control controller + LMS software
Weight2.2 kg5.2 kg5.2 kg
Device height490 mm1000 mm1000 mm
Maximum device diameter120 mm250 mm250 mm
Body material304L stainless steel body and nickel-plated copper strike tipStainless steelStainless steel
Model namesActive 1D+12-Active 1D+25-Active 1D+45-Active 1D+60Active2D 30 - Active2D 60Active4D 30 - Active4D 60

The table is based on the manufacturer's technical documents. The protection radius of each model must be calculated for the specific project to NF C 17-102, according to the protection level and installation height. For your convenience, the coverage radius table for each model, at different protection levels and heights and for the ΔT of that device, is on the page introducing that device.